62
AK-CC 210
Manual RS8EP502 © Danfoss 12-2015
21
*) Can only be set when regulation is stopped (r12=0)
**) Can be controlled manually, but only when r12=-1
***) With access code 2 the access to these menus will be limited
Factory setting
If you need to return to the factory-set values, it can be done in this way:
- Cut out the supply voltage to the controller
- Keep both buttons depressed at the same time as you recon nect the supply voltage
1
2
3
4
5
6
7
8
9
10
Input signal on DI1. Function:
0=not used. 1=status on DI1. 2=door function with alarm when
open. 3=door alarm when open. 4=defrost start (pulse-signal).
5=ext.main switch. 6=night operation 7=change reference
(activate r40). 8=alarm function when closed. 9=alarm function
when open. 10=case cleaning (pulse signal). 11=forced cooling
at hot gas defrost.
o02
1
11
0
Network address
o03
0
240
0
On/O
ff switch (Service Pin message)
IMPOR
TANT! o61
must
be set prior to o04
o04
OFF
ON
OFF
Access code 1 (all settings)
o05
0
100
0
Used sensor type (Pt /PTC/NTC)
o06
Pt
ntc
Pt
Display step = 0.5 (normal 0.1 at Pt sensor)
o15
no
yes
no
Max hold time after coordinated defrost
o16
0 min
60 min
20
Select signal for display view. S4% (100%=S4, 0%=S3)
o17
0%
100%
100%
Input signal on DI2. Function:
(0=not used. 1=status on DI2. 2=door function with alarm when
open. 3=door alarm when open. 4=defrost start (pulse-signal).
5=ext. main switch 6=night operation 7=change reference
(activate r40). 8=alarm function when closed. 9=alarm function
when open. 10=case cleaning (pulse signal). 11=forced cooling
at hot gas defrost.). 12=coordinated defrost)
o37
0
12
0
Configuration of light function (relay 4)
1=ON during day operation. 2=ON / OFF via data communica-
tion. 3=ON follows the DI-function, when DI is selected to door
function or to door alarm
o38
1
3
1
Activation of light relay (only if o38=2)
o39
OFF
ON
OFF
Rail heat On time during day operations
o41
0%
100%
100
Rail heat On time during night operations
o42
0%
100%
100
Rail heat period time (On time + Off time)
o43
6 min
60 min
10 min
Case cleaning. 0=no case cleaning. 1=Fans only. 2=All output
Off.
***
o46
0
2
0
Selection of EL diagram. See overview page 6
*
o61
1
10
1
Download a set of predetermined settings. See overview next
page.
*
o62
0
6
0
Access code 2 (partly access)
***
o64
0
100
0
Save the controllers present settings to the programming key.
Select your own number.
o65
0
25
0
Load a set of settings from the programming key (previously
saved via o65 function)
o66
0
25
0
Replace the controllers factory settings with the present set-
tings
o67
OFF
On
OFF
Service
Status codes are shown on page 17
S0-S33
Temperature measured with S5 sensor
***
u09
Status on DI1 input. on/1=closed
u10
Temperature measured with S3 sensor
***
u12
Status on night operation (on or off ) 1=closed
***
u13
Temperature measured with S4 sensor
***
u16
Thermostat temperature
u17
Read the present regulation reference
u28
Status on DI2 output. on/1=closed
u37
Temperature shown on display
u56
Measured temperature for alarm thermostat
u57
Status on relay for cooling
**
u58
Status on relay for fan
**
u59
Status on relay for defrost
**
u60
Status on relay for railheat
**
u61
Status on relay for alarm
**
u62
Status on relay for light
**
u63
Status on relay for valve in suction line
**
u64
Status on relay for compressor 2
**
u67
Summary of Contents for CHINO TY3
Page 6: ...6 Cut and Plan Views ...
Page 8: ...8 Spec Sheet ...
Page 9: ...9 01 01 ...
Page 10: ...10 0 1 0 0 1 1 1 2 0 1 ...
Page 11: ...11 0 1 0 23 43 5 0 1 0 23 43 5 5 5 1 6 1 1 7 23 43 ...
Page 12: ...12 0 1 23 23 1 23 23 1 0 1 4 5 0 4 6 0 4 4 4 ...