Safety equipment
8.7 Dismantling the front handle and
start inhibitor - LiHD60X / LiHD70X
1
Dismantle the front handle and the right chassis
half.
See Chapter 7.5 - 7.6.
2
Dismantle the gear housing and motor.
See Chapter 10.2.
3
Uncouple the handle cables (A) from the control
unit and remove them through the hole (B) in the
chassis.
See figure 7.
4
Loosen the screws (10x) and carefully lift off the
handle half.
See figure 8.
5
Lift the relay with cables (C) and the loop (D) out of
the handle.
See figure 9.
6
Lift the start inhibitor (E), plastic clips (F 3x),
springs (G 3x) and spring (H) over the screw tower
out of the handle.
See figure 10.
Fig.7
Fig.8
Fig.9
Fig.10
A
B
WARNING!
Exercise care to ensure the spring
does not fly out and causes person-
al injury. Wear protective goggles!
Summary of Contents for LiHD50