English
–
55
11 Troubleshooting - LiHD 50, 60X, 70X
Troubleshooting
Symptom
Possible causes
Recommended actions
Product cannot be activated. No
LED´s light up when pressing the on/
off button.
Broken battery
1. Check battery by pressing the
status button. Minimum 1 green LED
should be visible. See also Battery
and charger
Bad connection between battery and
product
2. Make sure power connectors
between battery and product are
not damaged and free from dirt. See
picture #1 in appendix.
Bad connection in keypad connector 3. Make sure the keypad connector
is properly assembled, dry, not da-
maged and free from corrosion. See
picture #2 in appendix.
Broken keypad
4. Replace keypad
Damage to multiwire cable between
control unit and keypad/trigger
switch
5. Repair/replace multiwire cable.
(Only if visible damage are present)
Short circuit in control unit
6. Replace control unit
Electric motor does not react when
applying the trigger
Front handle not activated
1. Activate and hold the front handle
when applying trigger
Bad connection in trigger switch
signal connector
2. Make sure the trigger switch sig-
nal connector is properly assembled,
dry, not damaged and free from cor-
rosion. See picture #3 in appendix
Motor connector not correctly as-
sembled
3. Make sure the motor connector(s)
are correctly assembled. See picture
#6 in appendix.
Internal damage to trigger switch
4. Replace trigger switch
Short circuit in control unit
5. Replace control unit
Electric motor jerks shortly when
applying the trigger, then stops
Short circuit in control unit
Replace control unit
Product shuts off when applying load Bad connection between battery and
product
Make sure power connectors bet-
ween battery and product are not
damaged and free from dirt. See
picture #1 in appendix.
Keypad lights flicker
Bad connection in keypad connector 1. Make sure the keypad connector
is properly assembled, dry, not da-
maged and free from corrosion. See
picture #2 in appendix.
Short circuit in keypad
2. Replace keypad
Unstable motor speed
Bad connection in trigger switch
signal connector
1. Make sure the trigger switch sig-
nal connector is properly assembled,
dry, not damaged and free from cor-
rosion. See picture #3 in appendix
Damaged or worn trigger switch
2. Replace trigger switch
Warning triangle on keypad blinks
continuous
Over temperature
1. Wait until product cools off (Max.
5 min)
Too low temperature on control unit
or battery
2. Make sure product or battery are
not colder than -10°C
Front handle safety switch jammed
in active position
3. Disassemble front handle and
remove possible dirt
Summary of Contents for LiHD50
Page 1: ...Workshop Manual English LiHD50 LiHD60X LiHD70X ...
Page 2: ......
Page 5: ...English 5 Index ...
Page 21: ...English 21 Diagnosis and troubleshooting ...
Page 39: ...English 39 ...
Page 43: ...English 43 Fig 9 Fig 8 LiHD60X LiHD70X Repair instructions LiHD60X LiHD70X ...
Page 60: ...2012W33 115 73 09 26 ...