56 – English
Warning triangle on keypad blinks
shortly after activation, where after
the product shuts off
Trigger is applied during activation
1. Activate the product without apply-
ing the trigger simultaneously
Water in trigger switch signal con-
nector
2. Disconnect and dry trigger switch
signal connector, reassemble. See
picture #3 in appendix
Short circuit in keypad
3. Replace keypad
Short circuit in trigger switch
4. Replace trigger switch
Warning triangle on keypad blinks
shortly after activation, where after
the product hangs up with the green
led on
Bad communication signal between
battery and product
1. Make sure power connectors
between battery and product are
not damaged and free from dirt. See
picture #1 in appendix.
2. Make sure the small cables bet-
ween power connector and control
unit are not loose or damaged. See
picture #6 in appendix
Product works but there are no indi-
cation light on the keypad
Bad connection in keypad connector 1. Test the keypad function in Bat-
tery Diagnostic Tool. Make sure
the keypad connector is properly
assembled, dry, not damaged and
free from corrosion. See picture #2
in appendix.
Broken keypad
2. Replace keypad
Product activates immediately when
battery is inserted, without pressing
the keypad
Short circuit in keypad
Replace keypad
Warning triangle on keypad shows a
fixed red light
Permanent error codes prevents the
product from running
1. Erase error codes in diagnostic
tool
Broken control unit
2. Replace control unit
Product shows fixed red light after
installing a new control unit
Spare part comes without software
Use diagnostic tool to install soft-
ware
Troubleshooting
Summary of Contents for LiHD50
Page 1: ...Workshop Manual English LiHD50 LiHD60X LiHD70X ...
Page 2: ......
Page 5: ...English 5 Index ...
Page 21: ...English 21 Diagnosis and troubleshooting ...
Page 39: ...English 39 ...
Page 43: ...English 43 Fig 9 Fig 8 LiHD60X LiHD70X Repair instructions LiHD60X LiHD70X ...
Page 60: ...2012W33 115 73 09 26 ...