WARNING!
The battery must always be removed
for service/repair work and may only
be replaced once the machine has
been completely assembled again!
WARNING!
Do not short circuit the battery!
Never unscrew the battery!
Never fit a damaged battery!
Replace a damaged battery!
Diagnosis and troubleshooting
6 Diagnosis and troubleshooting
Fig.2
Fig.1
6.1 Remove the battery
Press in the catches and remove the battery.
See figure 1.
6.2 Connect the diagnostic tool -
LiHD60X / LiHD70X
1
Connect the adapter cable for the diagnostic tool to
the battery and the battery contact on the machine.
Connect cable (A) to the diagnostic tool for trouble-
shooting the machine.
Connect cable (B) to the diagnostic tool for trouble-
shooting the battery.
NB! Refer to the manual for the Diagnostic Tool
Battery for detailed instructions and follow the
instructions in the diagnostic tool.
See figure 2.
2
Diagnose/troubleshoot according to the diagnostic
tool instructions and make any necessary repairs
as instructed in the relevant chapter in this manual.
6.3 No signal to diagnostic tool
1
Check that the contact on the battery and the bat-
tery contact on the machine are intact and clean.
Replace the battery or alternatively the control
unit on the machine if there is any damage to the
contact.
2
Check that the cable to the diagnostic tool is intact
and clean. Replace the cable if it is damaged.
3
Restart the computer/Reinstall the software.
2
1
1
A
B
Summary of Contents for LiHD50
Page 1: ...Workshop Manual English LiHD50 LiHD60X LiHD70X ...
Page 2: ......
Page 5: ...English 5 Index ...
Page 21: ...English 21 Diagnosis and troubleshooting ...
Page 39: ...English 39 ...
Page 43: ...English 43 Fig 9 Fig 8 LiHD60X LiHD70X Repair instructions LiHD60X LiHD70X ...
Page 60: ...2012W33 115 73 09 26 ...