6 FORK, TRIPLE CLAMP
Removing the fork �rotector
-
Remove screws
O
and take
off
the clamp.
-
Remove screws
8
on the left fork leg and take
off
the left
fork protector.
-
Remove screws (D on the right fork leg and take
off
the right
fork protector.
..
Installing the fork �rotector
6.9
Performing a fork service
20
i
I!
Ii
800462-01
-
Position the fork protector on the left fork leg. Mount and
tighten screws
O.
Guideline
Remaining screws,
chassis
M6
10 Nm (7.4 lbf ft)
-
Position the brake line, wiring harness, and clamp. Mount and
tighten screws
8.
-
Position the fork protector on the right fork leg. Mount and
tighten screws (D.
Guideline
Remaining screws,
chassis
Condition
M6
The fork legs have been removed.
-
Disassemble the fork legs. (
a
p. 21)
-
Remove the spring. (
a
p. 23)
-
Disassemble the cartridge. (
a
p. 24)
-
Disassemble the piston rod. (
!l.,!
p. 25)
10 Nm (7.4 lbf ft)
-
Disassemble the hydrostop unit. (
!l.,!
p. 26)
-
Disassemble the seal ring retainer. (
!l.,!
p. 27)
-
Check the fork legs. (
IUI
p. 27)
- Assemble the seal ring retainer. (
IUI
p. 29)
- Assemble the hydrostop unit. (
IUI
p. 29)
Assemble the piston rod. (
IUI
p. 30)
- Assemble the cartridge. (
IUI
p. 31)
Assemble the fork legs. (
0