II
•
·7
1
-1
201399-10
9 SHOCK ABSORBER, SWINGARM
Clamp the control lever as shown in the figure.
✓ The
External tank
(D
control lever is
on
Closed, Damper
8
on Vacuum,
and
Oil reservoir
0
on Vacuum.
Operate the
On/Off
switch (D.
✓ The vacuum pump process starts.
✓ Pressure gauge @ drops to the specified value.
I
< 0 bar
✓ The vacuum gauge
fD
falls to the specified value.
14
mbar
Measure distance
6)
between the floating piston and reser
voir hole with the special tool.
I
Depth micrometer (T1 07S) (
a
p. 364)
✓ The floating piston is positioned all the way at the bot
tom.
When the vacuum pressure gauge reaches the specified
value, turn the
Oil reservoir
control lever
0
to
Equalize pressure.
Guideline
14
mbar
✓ The pressure gauge increases to the specified value.
0 bar
When the pressure gauge reaches the specified value, turn
the
Damper
control lever
8
to Pressure.
Guideline
0 bar
✓ Oil is pumped into the damper.
✓ The pressure gauge increases to the specified value.
3 bar
When the pressure gauge reaches the specified value, turn
the
Damper
8
control lever to
Vacuum.
Guideline
3 bar
✓ The pressure gauge drops to the specified value.
0 bar
73