ELECTRICAL SYSTEM 14
111
Note
Environmental hazard
12 V batteries contain environmentally hazardous materials.
–
Do not dispose of 12 V batteries as household waste.
–
Dispose of 12 V batteries at a collection point for used batteries.
Info
Even when there is no load on the 12 V battery, it discharges steadily.
The charging level and the method of charging are very important for the service life of the 12 V battery.
Rapid recharging with a high charging current shortens the service life of the battery.
If the charging current, charging voltage, or charging time is exceeded, the 12 V battery will be
destroyed.
If the 12 V battery is depleted by repeated starting, the 12 V battery must be charged immediately.
If the 12 V battery is left in a discharged state for an extended period, it will become deeply discharged
and suffer a loss of capacity, destroying the battery.
The 12 V battery is maintenance-free.
Preparatory work
–
Press and hold the switch-off button
while the engine is
idling until the engine stops.
–
Remove the air filter box cover. (
–
Remove the seat. (
–
Remove the 12-V battery.
F01568-10
Main work
–
Check the battery voltage.
» Battery voltage: < 9 V
–
Do not charge the 12 V battery.
–
Replace the 12 V battery and dispose of the old 12 V
battery properly.
» If the specifications have been met:
Battery voltage:
≥
9 V
–
Connect the battery charger to the 12 V battery.
Switch on the battery charger.
Guideline
The charging current, charging voltage, and charg-
ing time must not be exceeded.
Maximum charging volt-
age
14.4 V
Maximum charging cur-
rent
3.0 A
Maximum charging time
24 h
Recharge the 12 V bat-
tery regularly when the
motorcycle is not being
used
6 months
(EU) battery charger (26529974000)
Alternative 1
(US) battery charger (26529974500)
These battery chargers test whether the 12 V bat-
tery retains its voltage. It is also impossible to over-