6
FORK, TRIPLE CLAMP
200685-10
-
Measure the outside diameter at multiple locations of the inner tube.
Outside diameter of inner tube
47.975 ... 48.005 mm (1.88878 ...
1.88996 in)
If the measured value is smaller than the specified value:
-
Change the inner tube.
-
Measure the run-out of the inner tube.
I
Inner tube run-out
I
$ 0.20 mm ($ 0.0079 in)
If the measured value is larger than the specified value:
-
Change the inner tube.
-
Measure the inside diameter at multiple locations of the outer tube.
I
Inside diameter of outer tube
I
$ 49.20 mm ($ 1.937 in)
If
the measured value is larger than the specified value:
-
Change the outer tube.
-
Check the outer tube for damage.
If
there is damage:
-
Change the outer tube.
-
Check the surface of the sliding bushings.
23
If
the bronze-colored layer
G
under sliding layer
0
is visible or the surface
is rough:
�
e
200665-10
200666-10
-
Change the sliding bushings.
-
Check the spring length.
Guideline
I
Spring length with preload spacer(s)
I
480 mm (18.9 in)
If
the measured value is larger than the specified value:
-
Reduce the thickness of the preload spacers.
If
the measured value is smaller than the specified value:
-
Increase the thickness of the preload spacers.
Assemblin the seal rin retainer
Info