22
ELECTRIC ST ARTER
195
22.1
Checkin the starter motor
303120-10
Condition
The starter motor has been removed.
- Connect the negative cable of a 12 volt power supply to the housing of the starter
motor. Connect the positive cable of the power supply briefly with the connec
tor
O
of the starter motor.
If the starter motor does not turn when the circuit is closed:
- Change the starter motor.