104 72 72-26
21
Setting the feed lifting in relation to the needle
Check
Problems associated with delivery amount, stitch unbalance and needle breakage, make the following check:
Make sure hair line marking on feed cam (A) match correctly with marking of arm shaft (B).
Adjustment
1. Remove the face plate, free arm cover, base plate, back cover and front cover.
2. Loosen screw (a) in the feed cam (A).
2. Turn the feed cam (A) until the the line in it comes right in front of the line in the arm shaft (B).
3. Lift needle to its highest position.
4. Loosen screw (b) and make sure hair line marking on feed lifting rock cam (C) match correctly with marking of feed
rock crank (D).