10
104 72 72-26
Presser bar height and alignment
Check
1. Raise the presser foot lever (A).
2. The distance between the presser foot (C) and the needle plate (D) should be 6.0-6.2 mm.
Adjustment
1. Remove the face cover.
2. Remove lamp bracket.
3. Raise the presser foot lever and loosen the 3mm Allen screw (E) on the side of the presser bar holder.
Adjust the distance between the zigzag foot (C) and the needle plate (D) to 6.0-6.2 mm.
4. Tighten the screw (E) securely.
5. Attach the lamp bracket and face cover.
NOTE! When you tighten the screw (E), make sure that both sides of the presser foot are parallel to the feed dog slots
(F) on the needle plate.
( B )
( A )
( E )
6.0- 6.2 mm
&
&
#
$