46
®
Press ENTER. The display will then show:
Press ENTER with
YES
capitalized, and the
controller will return to Auto Operational
status. If irrigation is scheduled to be running
when you Resume, it will begin irrigating. It is
technically possible (though unlikely) for a
controller to be in both “Suspend” and “Pause”
at the same time. If that is the case, repeat the
above procedure to clear first the Suspend, then
the Pause.
PAUSE mm:ss togo:
This indicates that
controller has stopped irrigation and all event
timers have been stopped. When a thirty-
minute Pause timer expires, or a Resume
command is entered, all events will resume
where they left off. This feature can be turned
on or off from the central computer control,
through the Field Controller Options selection
at the keypad, or via Maintenance Radio. See
Pause on page 7.
FCP AUTO INHIBIT:
This indicates that the
controller will not start any internal scheduled
programs. This mode can be started or stopped
from the controller keypad (see Set FCP
Inhibit on page 13), or the central computer.
Consult software documentation for details on
enabling and disabling this mode from the
central computer.
Comm is muted:
This indicates that the
controller will not initiate any communication
to a central controller. This message is only
cleared by an internal five-minute timer or by a
command from a central computer. This mode
is started or stopped by the central computer
and cannot be changed or cleared at the con-
troller keypad. Consult software documenta-
tion for details on this display.
No Network link:
This indicates that the
controller has not been in communication with
a central computer for 30 minutes. This mes-
sage is cleared by communicating with a
central computer, and may indicate power off
at the central or a communications failure at
either device.