To set FCP Inhibit: Press ENTER at the
“Set FCP
Inhibit?”
display. The display will then show:
The current selection will be capitalized (de-
fault is
OFF
). The
“on”
selection will be in
lower case. Press the TOGGLE button to switch
between
OFF
and
ON
. When it is correct, press
ENTER. The display will flash
“SAVED!”
and
your selection. After a moment, the display will
revert to:
You may now press the OPTIONS, BACK or
NEXTbuttons to view more options, or you may
press EXIT to leave the Edit Settings mode.
Set Response?: This will set the level of Field
Controller response to the central computer (if
it is present and communicating). In the Partial
Response setting, the field controller will report
any alarm conditions (such as Fuse Open,
Overload, Power Outage, etc.) if they occur.
In the Full Response setting, the Field Control-
ler will report all events as they occur, includ-
ing every station start and station stop, as well
as alarms. Full Response will also continuously
update the Station Status Display on the central
computer.
If full reports are not desired, or cause too
much communications “chatter”, you can set
this to Partial.
To set Response: Press ENTER at the
“Set
Response?”
display. The display will then show:
The current selection will be capitalized
(default is
PARTIAL)
. The
“full”
selection will
be in lower case. Press the TOGGLE button to
switch between
PARTIAL
and
FULL
. When it
is correct, press ENTER. The display will flash
“SAVED!”
and your selection. After a moment,
the display will revert to:
You may now press the OPTIONS, BACK, or
NEXT buttons to view more options, or you may
press EXIT to leave the Edit Settings mode.
Set MR Runtime?: MR = Maintenance
Radio. This determines the time-out timer
setting for stations started by Maintenance
Radio without specified Run Times.
If you simply start a station with Maintenance
Radio without a specific run time (see Sending
a Maintenance Radio command on page 41)
and forget to turn it off, this setting will auto-
matically shut it off after the time shown, to
prevent flooding and damage. The default
value is 30 minutes. You may select a longer or
shorter setting, from 1 minute to 18 hours, for
this safety feature.
To set MR Runtime: Press ENTER at the
“Set MR Runtime?”
display. The display will
then show:
Type the number for the default Maintenance
Radio timer (example: 20 minutes) with the