Quick Checklist
Electrician
Installation Manual
Majestic Everglade Ceiling Fan
1. Ceiling fan is not installed to a solid-state wall controller. Neither leading nor
lagging edge controllers will give satisfactory performance. Wall controllers
must only be types approved for use by Hunter Pacific International.
2. The fan, optional fan light and bracket is earthed.
3. Fan and optional fan light are ran from the same phase and preferably the same
final circuit.
4. Mounting bracket must be firmly secured to a solid structure such as a concrete
ceiling, steel structure or timber framing. If additional bracing is added it must
be firmly secured to the rafters and not left floating on the ceiling. Special
mounts, such as T-hooks, are available for certain types of installation.
5. Fan blades are at least 2.1m (7feet) above floor level.
6. If fan is installed on a pull cord or wall controller, check the fan is operating
correctly on all three speeds using the pull cord or wall controller.
7. If light is installed. Check light switch is functioning properly.
8. If remote control is installed. Check the fan (and light if installed) is responding
to the remote control correctly.
9. If remote control is installed. Check where possible a separate isolation switch
has been installed for the fan.
10. Check electrician’s details have been recorded onto the back page of the
Owner’s Operations and Warranty Manual.
Electricians make sure everything on this checklist is ticked off before you leave the installation site.
If you have trouble installing our product please refer to the trouble shooting section on the previous
page first then phone the Hunter Pacific Warranty Line on 1300 360 280 (open 9am to 5pm EST).
DO NOT uninstall the fan and DO NOT return fan to retailer.
1.
Do not
attempt to operate the fan (or optional light kit) with any wall control that is
not approved by Hunter Pacific for use with its fans. DO NOT use solid state
controllers. The use of unapproved controllers will void your warranty.
2.
Do not
mix blade sets from one fan to another as this may upset the balance of
the fan. If only one blade is damaged you are still required to replace with a new set.