31
>>> SEQUENCE DWELL TIME
• Specify the sequence dwell time that is used when the SEQ key is pressed.
• The interval can be configured with a slider from Off (disable) to 60 seconds (default 10 seconds).
>>> EXIT PLAYBACK ON EVENT
• When set to On, the HVRM-S400E exits playback to display a live event.
>>> VGA MODE
• VGA mode can be changed to 4 different modes.
800 x 600 @ 56 / 800 x 75 @ 75 / 1024 x 768 @ 60 / 1280 x 1024 @ 60
>>> Playback Deinterlace
• Deinterlace enable / disable
The “Deinterlace Mode” only runs when the recording resolution is in Full D1.
In case of enable it, the Full D1 image with Pause condition the picture will have less tremor.
In case of keep press the Pause button continuously from Pause condition, the “Deinterlace Mode” can
be On/Off in Toggle condition.