Depth Offset
(Advanced)
Depth Offset
will adjust the digital depth readout to indicate depth from the
waterline or boat's keel. Enter a positive vertical measurement from the
transducer to the waterline to read the depth from the waterline. Enter a
negative vertical measurement from the transducer to keel to read the depth
from the keel. This menu choice is available only when in Advanced User Mode
(see
Setup Menu Tab: User Mode
.)
To change the Depth Offset setting:
1. Make sure you are in Advanced User Mode, then highlight Depth
Offset on the Setup menu.
2. Use the LEFT or RIGHT 4-WAY Cursor Control keys to change the Depth
Offset setting. (-10.0 to +10.0 feet or -3 to 3 meters
[International
Models only]
, Default = 0)
Aux. Temp. Offset
(Advanced)
Aux. Temp. Offset
will adjust the aux. temperature readout (the temperature on
the optional-purchase temperature probe or Temp/Speed accessory) by the
amount entered. This menu choice is available only when in Advanced User
Mode (see
Setup Menu Tab: User Mode.
)
To change the Aux. Temp. Offset setting:
1. Make sure you are in Advanced User Mode, then highlight Aux. Temp.
Offset on the Setup menu.
2. Use the LEFT or RIGHT 4-WAY Cursor Control keys to change the Aux.
Temp. Offset setting. (-10.0 to +10.0 degrees, Default = 0)
Summary of Contents for 797c2 SI/NVB
Page 1: ...797c2 GPS Chartplotter Operations Manual 797c2 GPS Chartplotter Operations Manual 531519 1_B...
Page 27: ...17 Submerged Barge with Dumped Logs Dumped logs Submerged barge...
Page 38: ...28 Structure ID represents weak returns in blue and strong returns in red...
Page 183: ...173 Notes...
Page 184: ...174 Notes...
Page 185: ...175 Notes...
Page 186: ...176 Notes...
Page 187: ...177 Notes...
Page 188: ...178 Notes...