5. Clamp inverted tool firmly in a vice,
(use fibre vice clamps). Apply a thin
coating of grease to the O Ring 53 on the
Cylinder Cap 51. Use a 28 mm socket
and torque wrench to tighten the Cylinder
Cap 51 clockwise into the Air Cylinder.
Tighten to 25 to 30 Ft.lb (33.90 to 40.68
Nm).
6. Stand tool on a level surface (e.g.
workbench), then partly unscrew Bleed
Plug 9 to release any excess hydraulic
pressure. Re-tighten Bleed Plug.
7. Connect tool to a suitable air suply and
Cycle tool several times to check for any
leaks and correct function. Continue
testing tool in accordance with the section
in this manual Preparation for Use