Foreign material introduced in the Hydraulic Unit will
result in poor performance and down time for repair.
To avoid this:
Clean the area around the filler cap
with a filter, keep quick-disconnect couplers clean by
couplers before connecting them.
Good Service Practices
Trade Names
WHERE THE FOLLOWING TRADE NAMES ARE USED IN THIS MANUAL, PLEASE NOTE:
WHERE THE FOLLOWING TRADE NAMES ARE USED IN THIS MANUAL, PLEASE NOTE:
Loctite
is a registered trademark of Henkel IP & Holding GMBH.
is a registered trademark of The Chemours Company FC, LLC.
BEFORE EACH USE:
2. Inspect hoses for damage & wear. If hoses show wear
deeper than the surface level, they must be replaced.
3. Check the entire system and repair any leaks.
4. Check electrical cord and extension for abrasion and
replace as required.
Set-up Instructions
WARNINGS:
for PULL and RETURN pressures. Severe personal injury may occur if excessive pressures cause violent
failure of equipment. Higher than normal pressures will cause premature wear of equipment. If the
maximum pressure is exceeded, violent failure of fastening system may occur. This may cause severe
personal injury.
Electric Motor
WARNING:
To avoid injury:
Electrical work must be done by a
Disconnect power supply before
removing the motor casing cover or
performing repairs or maintenance.
Hydraulic Connections
1. Clean the areas around the oil ports of the pump.
2. Inspect the threads and fittings for signs of wear or
damage and replace as needed. Clean all hose ends and
couplers.
Checking Hydraulic Fluid and Filling the Bladder
1. Thoroughly clean the area around the filler cap with a clean cloth to prevent contamination of the oil by
foreign particles.
2. Make sure the valve control lever is in the neutral position.
A. Remove the filler cap.
(If no oil is visible, continue to step B)
B. Insert a clean funnel with filter or strainer.
C. Fill the bladder completely with hydraulic fluid to the top of the filler. All air must be out of the bladder.
D. Replace filler cap.
Important:
Tighten filler cap 1/2 - 1 turn after o-ring contacts sealing surface.
Overtightening can cause pump damage.