12. Error solutions
12.1
Possible errors
If an error in the access point occurs, the error code
is displayed on the hand terminal:
Error 001
wrong positioning of the emergency
stop relay
Error 002
wrong positioning of the safety relay
Error 004
emergency stop due to disconnec-
tion
Error 008
discrepancy
between
the
two
controllers
Error 016
24V supply is missing or defect in
charging electronic
Keyboard Err failing button or a button was
pressed during turn on of the hand
terminal.
If several errors occure at the same time, the sum of
error codes is displayed, i.e. error 002 and error
004, the display will read error 006!
12.2
Cause of errors
Error 1 and 2 indicate problems with the hardware in
the access point. Should this occur frequently - call
for service.
Error 4 indicates a radio wave interruption.
The following steps can assist:
-
increase transmitting power
-
increase range setting
-
change channel
Error 8 is a discrepancy in the transmitting protocol
caused either by the access point or the hand
terminal - call for service.
Error 16 points out a missing supply of the charging
control. Check the connections.
This error is also possible if the internal watchdog
functions of the access point detect an error
– call for service!
Is there a frequent emergency stop without error
during the operation (hand terminal is on), the cause
can be an integrated exit control in the access point
– call for service!
An emergency stop while the hand terminal is in the
charging station can be caused by dirty loading
contacts or a defect of the emergency stop button.
If there is no more connection possible, there might
be a defective internal fuse on the access point
(micro fuse 5 x 20, 0,5AT).
12.3
LOW - BATT display
If during operation the LOW - BATT is displayed, the
hand terminal should be returned to the charging
station!
Further operation for approx. 3 hours is still possible
before the hand terminal shuts down and causes an
emergency stop.
12.4
No function
The following possibilities have to be evaluated:
1.
The hand terminal cannot build up a
connection to the access point
-
check the cable
-
check internal fuse in the access point (fine
fuse 5 x 20, 0,5AT)
-
check channel setting
-
Compare the serial number of access point and
hand terminal (they need to be the same!)
-
check rechargeable batteries in the hand
terminal
2.
Machine does not react
-
confirm error codes on the machine control
-
turn on control voltage
-
check the Profibus connection
-
check the LED's of the connecting adaptor
(see 16.1)