background image

Operating manual HBG 800-DP  

Rev. 05 - 08/18 

Hubitron Steuerungstechnik 

Hubitron Steuerungstechnik, Hauptstr. 4/1, D-89611 Obermarchtal, Germany, Tel. +49(0)7375/922066, FAX +49(0)7375/922077 

6 of 16 

7.2  Out of operation 

Is the hand wheel cut off from the supply voltage for 
a  longer  time  period,  it  is  very  important  to  attach 
the  magnet  with  an  adhesive  tape  to  the  hand 
terminal.  The  magnet  causes  an  internal  reed 
contact  to  disconnect  the  supply  voltage.  This  way 
damage to the accus is avoided. 
For correct placement: 

push and hold safety buttons – LED's are on. 

run  with  the  magnet  over  the  right  side  of  the 
hand terminal in height of the housing slits until 
the LED's turn off. 

fix  the  magnet  in  this  position  with  adhesive 
tape. 

push  the safety buttons again, if LED's are off, 
the magnet is installed correctly. 

8.  Operation 

8.1  Switching on and off of the hand 

terminal 

The  hand  terminal  is  switched  on  with  one  of  the 
safety buttons (12 or 13). 
The  connection  builds  up  after  both  safety 
buttons are released again! 
The switching off is possible in two ways: 
1. 

push the emergency stop 

2. 

return  the  hand  terminal  to  the  charging 
station 

 
Remark: 
To  avoid  an  accidental  emergency  stop  the  hand 
terminal has to be turned on with the safety buttons 
before you take it out of the charging station! To do 
this,  simply  push  one  of  the  safety  buttons  and 
release again. 
 
After  enabling  the  hand  wheel  on  the  machine 
control it can be used. 
The assignment of the buttons and LED's has to be 
programmed  on  the  PLC  of  the  machine.  An 
example programm is available on the support CD. 

8.2  LCD display 

On the 2 line LCD display error codes and warnings 
are displayed. 
It  is  also  possible  to  display  user  information  like 
axis information and potentiometer positions.... 

9.  Set up 

9.1  Used buttons 

For the Set up the following buttons are used: 
 

 

safety buttons to

 

switch on 

enable set up 

enter 

change values 

exit set up 

 
 
 
 
 
 
 
 
 
 
 

 
 

 
 

9.2  Enter Set up 

If  you  enter  the  set  up,  the  communication  with  the 
machine  is  interrupted.  This  causes  an  emergency 
stop! 
 

Turn off hand terminal with the emergency stop 
button. Pull emergency stop button! 

Push and hold both buttons (2) 

Turn on the hand terminal with a quick push on 
the safetyl buttons (1) 

 
The display must show:   

SETUP 

 

 

 

 

 

 

Power 

 

9.3  Change Set up 

In  the  Set  up  the  following  menue  points  can  be 
selected: 
 
menue 

description 

setting range 

Power 

transmitting power 

0 – 7 

Kanal 

channel setting 

0 – 20 

Range 

range setting 

20 – 60 

Test-Nr 

test functions 

0 – 8 

 
o  start Set up menue as described in 9.2 
o  select menue point with b/- (4) 
o  enter menue point with button X (3) 
o  change value with b/- (4) 
o  confirm selection with button X (3) 
o  exit Set up with button 5 
 
When changing the channel be sure that the access 
point is turned on and within range! 

Summary of Contents for HBG 800-DP

Page 1: ...6 4 2 Pin assignment 5 7 Installation 5 7 1 Profibus installation 5 7 2 Out of operation 6 8 Operation 6 8 1 Switching on and off of the hand terminal 6 8 2 LCD display 6 9 Set up 6 9 1 Used buttons 6...

Page 2: ...10mW at 433 MHz max 5mW at 869 MHz Range approx 25 m adjustable 2 3 Charging station Dimensions l x w x h approx 190 x 95 x 55 Weight approx 100g Contacts 4 2 4 Connecting Adaptor HBG 800 DP Dimensio...

Page 3: ...l definition 5 button for hand wheel inching function with LED s 6 axis movement buttons 7 LCD display 8 encoder 9 axis selection buttons with LED s 10 feed spindle start stop the stop buttons are wor...

Page 4: ...ss setting The connecting adaptor HBG 800 DP is for mounting on a DIN rail The scope of supply includes a connecting cable with only one plug It has to be connected to X3 and X4 of the connecting adap...

Page 5: ...op Do not bend the loading station o Install the access point on the machine control panel near to the hand wheel interface preferably above the control panel Underneath the 2 covers 15 are 2 mounting...

Page 6: ...tation To do this simply push one of the safety buttons and release again After enabling the hand wheel on the machine control it can be used The assignment of the buttons and LED s has to be programm...

Page 7: ...ed 0 no test standard operation 1 measurement of the receiving field strength in operation access point must be running 2 autom search of the selected channel in access point The hand terminal is sear...

Page 8: ...inal walk up the operation range the maximum value should remain 23 If this is not the case repeat the measurement using a different channel To do this first switch off the hand terminal with an emerg...

Page 9: ...ts out a missing supply of the charging control Check the connections This error is also possible if the internal watchdog functions of the access point detect an error call for service Is there a fre...

Page 10: ...it to the charging station Once a month run the batteries from the hand terminal down without charging to LOW BATT this increases the strength of the battery charge Change rechargeable batteries ever...

Page 11: ...ation of the manufacturers declaration and warranty There is no liability for any damage caused The end user of the superior working unit is responsible to comply in each individual application with t...

Page 12: ...n LED2 transmitting LED3 hand terminal in charging station blinking fast charge LED4 hand terminal in charging station blinking error in supply voltage or defekt in the unit In addition each relay has...

Page 13: ...foil HBG 800 DP 3b adhesive stickers for front foil 4 magnet for disconnecting accus 5 rotary encoder 6 safety button 7 magnetic clamp with hook 8 cover 9 antenna long 433 MHz 10 antenna short 868 MHz...

Page 14: ...ol The operation is prohibited as long as the conformity of the end product with regulation 2006 42 EC is not ascertained We confirm the conformity of the above described product with RoHS regulation...

Page 15: ...ive you can use the A B signals on the connector X2 This signals can be connected directly to the control unit Siemens 810D 840D X121 pin 15 18 34 37 length of data 2 byte dataword possible values 327...

Page 16: ...al HBG 800 DP Rev 05 08 18 Hubitron Steuerungstechnik Hubitron Steuerungstechnik Hauptstr 4 1 D 89611 Obermarchtal Germany Tel 49 0 7375 922066 FAX 49 0 7375 922077page 16 of 16 Connecting example Sie...

Reviews: