exchange the 3 batteries, ensure correct 
polarisation! 

 

assemble unit vice versa 

return the hand terminal to the charging station 
to load the batteries 

 
Remark: 
In  accordance  with  the  battery  regulations  dated. 
01.10.98 old batteries & rechargeable batteries must 
either  be  returned  to  the  store  or  given  to  a 
communal  collecting  place.  They  are  not allowed to 
be discarded in regular garbage! 

14. Frequency table 

channel-no. 

frequency (MHz) 

antenna 

869,75  

short 

869,85  

short 

869,94  

short 

869,35  

short 

433,10 

long 

433,20 

long 

433,30 

long 

433,40 

long 

433,50 

long 

433,60 

long 

10 

433,70 

long 

11 

433,80 

long 

12 

433,90 

long 

13 

434,00 

long 

14 

434,10 

long 

15 

434,20 

long 

16 

434,30 

long 

17 

434,40 

long 

18 

434,50 

long 

19 

434,60 

long 

20 

434,70 

long 

15. Safety instructions 

-  Before  making  changes  on  the  machine  or  the 

hand  terminal  make  sure  there  is  no  voltage!  On 
the  hand  terminal  the  emergency  stop  must  be 
pressed. 

-  self made reconstructions or other changes on the 

unit  cause  an  immediate  expiration  of  the 
manufacturers  declaration  and  warranty.  There  is 
no liability for any damage caused! 

-  The  end  user  of  the  superior  working  unit  is 

responsible 

to 

comply 

in 

each 

individual 

application  with  the  national  and  international 
safety and accident regulations. 

-  During  the  machine  planning  and  the  use  of  a 

manual  unit  the  valid  specific  national  and 
international  safety  and  accident  regulations  have 
to be followed, i.e. 

EN 60204, Electronic equipment of machines 

EN 292,   Safety of machines 

EN 954,   Safety relevant parts of controls 

-  A  m

achine  movement  through  the  hand  wheel  is 

only allowed if both safety buttons are pressed!

 

-  It is not allowed to give orders causing dangerous 

situations  with  the  safety  buttons  only.  A  second 
deliberate start up command is required

.

 

-  When  handling  the  hand  wheel  injuries  can  be 

caused  through  the  strong  pull  of  the  magnet. 
Keep a safe distance with a pace maker, magnetic 
data  supports  (loss  of  data),  electrical  and 
electronic units. 

-  The operator of the hand wheel must always have 

a clear view to the tool and the work piece. 

-  „Remote  controls“  from  a  large  distance  are  not 

permitted.  There  is  no  liability  for  any  damage 
caused. 

-  Always  return  the  hand  terminal  to  the  charging 

station  when  the  machine  is  working  in  automatic 
operation! 

On  machines  with  only  one  emergency  stop 
circuit  both  emergency  stop  contacts  HBG 
800-DP have to be connected in series 

 

Summary of Contents for HBG 800-DP

Page 1: ...6 4 2 Pin assignment 5 7 Installation 5 7 1 Profibus installation 5 7 2 Out of operation 6 8 Operation 6 8 1 Switching on and off of the hand terminal 6 8 2 LCD display 6 9 Set up 6 9 1 Used buttons 6...

Page 2: ...10mW at 433 MHz max 5mW at 869 MHz Range approx 25 m adjustable 2 3 Charging station Dimensions l x w x h approx 190 x 95 x 55 Weight approx 100g Contacts 4 2 4 Connecting Adaptor HBG 800 DP Dimensio...

Page 3: ...l definition 5 button for hand wheel inching function with LED s 6 axis movement buttons 7 LCD display 8 encoder 9 axis selection buttons with LED s 10 feed spindle start stop the stop buttons are wor...

Page 4: ...ss setting The connecting adaptor HBG 800 DP is for mounting on a DIN rail The scope of supply includes a connecting cable with only one plug It has to be connected to X3 and X4 of the connecting adap...

Page 5: ...op Do not bend the loading station o Install the access point on the machine control panel near to the hand wheel interface preferably above the control panel Underneath the 2 covers 15 are 2 mounting...

Page 6: ...tation To do this simply push one of the safety buttons and release again After enabling the hand wheel on the machine control it can be used The assignment of the buttons and LED s has to be programm...

Page 7: ...ed 0 no test standard operation 1 measurement of the receiving field strength in operation access point must be running 2 autom search of the selected channel in access point The hand terminal is sear...

Page 8: ...inal walk up the operation range the maximum value should remain 23 If this is not the case repeat the measurement using a different channel To do this first switch off the hand terminal with an emerg...

Page 9: ...ts out a missing supply of the charging control Check the connections This error is also possible if the internal watchdog functions of the access point detect an error call for service Is there a fre...

Page 10: ...it to the charging station Once a month run the batteries from the hand terminal down without charging to LOW BATT this increases the strength of the battery charge Change rechargeable batteries ever...

Page 11: ...ation of the manufacturers declaration and warranty There is no liability for any damage caused The end user of the superior working unit is responsible to comply in each individual application with t...

Page 12: ...n LED2 transmitting LED3 hand terminal in charging station blinking fast charge LED4 hand terminal in charging station blinking error in supply voltage or defekt in the unit In addition each relay has...

Page 13: ...foil HBG 800 DP 3b adhesive stickers for front foil 4 magnet for disconnecting accus 5 rotary encoder 6 safety button 7 magnetic clamp with hook 8 cover 9 antenna long 433 MHz 10 antenna short 868 MHz...

Page 14: ...ol The operation is prohibited as long as the conformity of the end product with regulation 2006 42 EC is not ascertained We confirm the conformity of the above described product with RoHS regulation...

Page 15: ...ive you can use the A B signals on the connector X2 This signals can be connected directly to the control unit Siemens 810D 840D X121 pin 15 18 34 37 length of data 2 byte dataword possible values 327...

Page 16: ...al HBG 800 DP Rev 05 08 18 Hubitron Steuerungstechnik Hubitron Steuerungstechnik Hauptstr 4 1 D 89611 Obermarchtal Germany Tel 49 0 7375 922066 FAX 49 0 7375 922077page 16 of 16 Connecting example Sie...

Reviews: