1.

Establish connection

The  following  displays  are  possible  for  the

connecting status:

not connected:

no connection

connected:

connection established

Timeout:

connection disrupted

2.

Transmit  data record to table

On  the  chosen  measuring  points  each  data  record

must be transmitted to the table.

3.

Print chart

A window appears for customer and machine data:

Enter  the  customer  and  machine  data  and  confirm

with OK.

After  that  the  measuring  chart  can  be  printed.

Example is attached.

14.3.1 Other functions

delete all data in the table
save active table

load saved table

close program

shows the information window

Information window:

14.3.2 Delete individual records

In the table mark data record with a mouse click:

delete with DEL

Summary of Contents for ACS-1000

Page 1: ...ation and arrangement 4 8 1 1 Installation 4 8 1 2 Arrangement 5 8 2 Wire spanning and arranging 5 8 3 Height compensation 6 8 3 1 Adjustment of incline 6 8 4 Length compensation 7 8 4 1 Delete compen...

Page 2: ...t case ACS 1000 1 Protector cap for sensor red 1 Light protector cap black 1 Inbus key SW4 4 Optional equipment 4 1 Remote control ACS 1000 RC With the remote control ACS 1000 RC all relevant function...

Page 3: ...play This display appears for appr 2 seconds when the unit is switched on The SW version and the ID for the remote control is displayed 7 2 2 Main menu On the bottom the assignment of the function key...

Page 4: ...rmation the next instruction will follow back to the compensation menu 7 2 5 Starting menu Graphic display set display data to 0 set display data to absolut switch to text display back to the compensa...

Page 5: ...heet of paper DIN A4 position machine at the right outer stop arrange ACS 1000 that the laser beam remains within the reflection area A sideways deviation can be corrected by turning the ACS 1000 on t...

Page 6: ...ION Now do not move the Z axis anymore move machine slide up until H 4 5 mm and is displayed confirm with NOTE Is the deviation larger 0 1 mm the incline of the sensor head must be corrected with the...

Page 7: ...Is the length compensation not needed the last compensation data must be deleted start length compensation main menu delete data with 8 5 Start measurements Is the ACS 1000 arranged and compensated th...

Page 8: ...esp have accu changed change fuse chapter 12 1 send unit for service display non readable altered contrast Readjust contrast 11 Activity to avoid interruptions 1 If the unit is not in use cover the se...

Page 9: ...Charge goes off the charging process is finished 12 3 Change accu Is the accu running time considerably declining the accu might be defect and must be changed For an accu change the unit must be sent...

Page 10: ...3 5 Charge accu connect the provided charging unit type ACS 110 with the connector of the ACS 1000 RC connect charging unit with the electrical network The red LED Charge indicates the charging proces...

Page 11: ...tall the Software net Framework from Microsoft is required Is it not yet installed it will be automatically downloaded and installed during the installation Internet connection is required On the CD a...

Page 12: ...disrupted 2 Transmit data record to table On the chosen measuring points each data record must be transmitted to the table 3 Print chart A window appears for customer and machine data Enter the custom...

Page 13: ...ner Huber eMail Info Hubitron de www Hubitron de 02 08 2012 Manufacturer Hubitron Steuerungstechnik Hauptstr 4 1 89611 Obermarchtal Germany Product Alignment Calibration System ACS 1000 and Remote Con...

Page 14: ...sanleitung ACS 1000 Rev 1 0 08 12 Hubitron Steuerungstechnik Hubitron Steuerungstechnik Hauptstr 4 1 D 89611 Obermarchtal Tel 49 0 7375 922066 FAX 49 0 7375 922077 Seite 14 von 14 Attachment Measuring...

Reviews:

Related manuals for ACS-1000