13. Remote control ACS-1000 RC

The remote control ACS-1000 RC is available as an

optional equipment.

13.1 Technical Data

Dimensions (LxWxH) ................... appr. 143x140x40

Weight.....................................................appr. 700g

Power supply........................ 4x1,2V NiMh accu, AA

Display ............................................ LCD, 240 x 128

Operating elements ..................................5 foil keys

Running time ................................................... > 8 h

Radio connection 4 channels, SRD868MHz, <10mW

13.2 Scope of delivery

1

remote control ACS-1000 RC

1

charging unit ACS-1000 RC

1

USB cable

1

software CD

13.3 Operating elements

13.4 Operation

  turn on the ACS-1000

  turn on the ACS-1000 RC on the on-off switch

The  radio  connection  now  builds  up  automatically

and on the display the same display data shows as

on  the  ACS-1000.  Operation  and  menu  guide  are

identical.
On  the  display  in  the  upper  left  corner  the  accu

status, the radio connection and the accu warning of

the main unit ACS-1000 is displayed:

Symbols:

accu status

 / 

radio connection activ/disrupted
accu warning of the ACS-1000

13.5 Charge accu

  connect  the  provided  charging  unit,  type  ACS

110, with the connector of the ACS-1000 RC

  connect charging unit with the electrical network

The  red  LED  (Charge)  indicates  the  charging

process.  If  the  green  LED  (Ready)  shines,  the

charging process is finished.

13.6 Change accu

4  standard  NiMh  accus  size  AA  feed  the  power

supply  of  this  unit.  As  replacement  we  recommend

accus  from  Panasonic  with  a  capacity  of  min.

2100mAh.

  unscrew accu compartment with a coin

  pull the accu plug

  take out the accu pack and replace accus

NOTE:

In  accordance  with  the  battery  regulations  dated.

01.10.98 old batteries & rechargeable batteries must

either  be  returned  to  the  store  or  given  to  a

communal collecting place. They are not allowed to

be discarded in regular garbage!

13.7 Change ID

For the radio communication between the ACS-1000

and  the  remote  control  ACS-1000  RC  both  units

must have the same ID.

  shut off the ACS-1000 RC

  push and hold the function keys F1+F3

  turn on the ACS-1000 RC

With 

  or 

  change  the  marked  field.

With 

 change the field.

Confirm change with 

.

13.8 PC connection

When the unit is shut off connect  with the  provided

USB cable the USB connector with the PC, than turn

on the unit.

A virtual COM port is generated on the PC, through

this  port  the  communication  is  established  with  the

PC.

Summary of Contents for ACS-1000

Page 1: ...ation and arrangement 4 8 1 1 Installation 4 8 1 2 Arrangement 5 8 2 Wire spanning and arranging 5 8 3 Height compensation 6 8 3 1 Adjustment of incline 6 8 4 Length compensation 7 8 4 1 Delete compen...

Page 2: ...t case ACS 1000 1 Protector cap for sensor red 1 Light protector cap black 1 Inbus key SW4 4 Optional equipment 4 1 Remote control ACS 1000 RC With the remote control ACS 1000 RC all relevant function...

Page 3: ...play This display appears for appr 2 seconds when the unit is switched on The SW version and the ID for the remote control is displayed 7 2 2 Main menu On the bottom the assignment of the function key...

Page 4: ...rmation the next instruction will follow back to the compensation menu 7 2 5 Starting menu Graphic display set display data to 0 set display data to absolut switch to text display back to the compensa...

Page 5: ...heet of paper DIN A4 position machine at the right outer stop arrange ACS 1000 that the laser beam remains within the reflection area A sideways deviation can be corrected by turning the ACS 1000 on t...

Page 6: ...ION Now do not move the Z axis anymore move machine slide up until H 4 5 mm and is displayed confirm with NOTE Is the deviation larger 0 1 mm the incline of the sensor head must be corrected with the...

Page 7: ...Is the length compensation not needed the last compensation data must be deleted start length compensation main menu delete data with 8 5 Start measurements Is the ACS 1000 arranged and compensated th...

Page 8: ...esp have accu changed change fuse chapter 12 1 send unit for service display non readable altered contrast Readjust contrast 11 Activity to avoid interruptions 1 If the unit is not in use cover the se...

Page 9: ...Charge goes off the charging process is finished 12 3 Change accu Is the accu running time considerably declining the accu might be defect and must be changed For an accu change the unit must be sent...

Page 10: ...3 5 Charge accu connect the provided charging unit type ACS 110 with the connector of the ACS 1000 RC connect charging unit with the electrical network The red LED Charge indicates the charging proces...

Page 11: ...tall the Software net Framework from Microsoft is required Is it not yet installed it will be automatically downloaded and installed during the installation Internet connection is required On the CD a...

Page 12: ...disrupted 2 Transmit data record to table On the chosen measuring points each data record must be transmitted to the table 3 Print chart A window appears for customer and machine data Enter the custom...

Page 13: ...ner Huber eMail Info Hubitron de www Hubitron de 02 08 2012 Manufacturer Hubitron Steuerungstechnik Hauptstr 4 1 89611 Obermarchtal Germany Product Alignment Calibration System ACS 1000 and Remote Con...

Page 14: ...sanleitung ACS 1000 Rev 1 0 08 12 Hubitron Steuerungstechnik Hubitron Steuerungstechnik Hauptstr 4 1 D 89611 Obermarchtal Tel 49 0 7375 922066 FAX 49 0 7375 922077 Seite 14 von 14 Attachment Measuring...

Reviews:

Related manuals for ACS-1000