U8950 Maintenance Guide V1.0
9 Maintenance Records During Verification
2012-10-22
Huawei Proprietary and Confidential
46
Stage
Station of Fault
Faulty Item
Symptom
Solution
VN1
Upload
B03A
REG_S4 output
nothing, all voltages
were not stable,
and U1002
and U1402 were
short-circuited
U1002 and U1402 were found
connected. Report this problem to
R&D for further analysis.
VN1
Upload
Upload fails
U3801 was
short-circuited, and
VREG_S4 output
nothing.
U3801 was found defective, which is
reported to R&D for further analysis.
VN1
Upload
Upload fails
No port was found.
The VREG_S3 voltage was 3.6 V,
and VREG_S4 output nothing. It is
determined that U201 is faulty. Keep
the sample for further analysis.
VN1
MT
568214
The coaxial cable
was poorly
connected to the
sub-board.
Check with the production line and
R&D first, re-connect the cable to
the sub-board, and test again.
VN1
BT
300031
C3502 has a current
leakage of 1.5 mA.
Remove C3502 and test again.