U8950 Maintenance Guide V1.0
9 Maintenance Records During Verification
2012-10-22
Huawei Proprietary and Confidential
34
Stage
Station of Fault
Faulty Item
Symptom
Solution
V3
MMI
MMI01F
abnormal
display
The software was
poorly loaded.
The test was performed again after
the software was eliminated.
V3
MMI
MMI01E
display
malfunction
The LCD BTB
connector on the
main PCBA was
poorly soldered.
The BTB connector was re-soldered.
V3
MMI
MMI01D
automatic
restart or
power-off
The side key FPC
was short-circuited,
resulting in
automatic startup (or
turn-off).
The side key FPC was to be
replaced.
V3
MMI
MMI01B
startup failure
The side key FPC
was broken,
resulting in startup
failure after the
power key was
pressed.
The side key FPC was to be
replaced.
V3
MMI
MMI01B
startup failure
The board clip on
the front cover was
broken, resulting in
poor contact
between the board
and startup shrapnel
on the front cover.
The front cover was to be replaced.
V3
MMI
MMI01B
startup failure
The startup shrapnel
on the main PBCA
failed to contact the
FPC.
The startup shrapnel and FPC were
re-assembled.
V3
CT
CT20001Y
The test equipment
was unstable.
No current leakage was detected
when tested using a multimeter. The
test equipment was replaced and the
test then passed.
V3
CT
CT200011
The flash chip was
open soldered.
The test was performed again and no
interface was detected yet. However,
it passed after the flash chip was
re-soldered.
V3
CT
CT 200011
The resistor R3802
had a side effect.
The software was
not programmed
properly.
The test failed after the resistor was
re-soldered and passed after the
software was re-programmed.
V3
BT
BT367329
BER
A mis-test occurred.
The test was performed again.