HUAWEI TE40&TE50&TE60 Videoconferencing
Endpoint
Administrator Guide
4 Display Device and Camera
Issue 01 (2013-09-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
53
PTZ is an acronym for Pan, Tilt, and Zoom. A PTZ camera supports panning, tilting, and zooming
control.
The HD-VI port can only be connected to the HUAWEI VPC600 or VPC620. After connecting this
port to the HUAWEI VPC600 or VPC620, you can perform PTZ controls on and supply power to
the HUAWEI VPC600 or VPC620 without additional cables.
If you connect a port other than the HD-VI port to the camera, you must connect the cable used for
transmitting VISCA control signals to the COM port on your endpoint to perform PTZ controls on
the camera.
Each input port to be used for transmitting a video or a presentation can be specified on the
user interface. For details, see section
6.1.1 Designating the Dual Streams
Select a video input port on your endpoint based on the video format supported by the camera.
Then connect the camera to your endpoint using the cable provided.
4.4 Configuring Video Input
Correct video input settings enable your endpoint to properly display video input from the
video input ports.
Procedure
Step 1
Choose
Advanced
>
Settings
>
Video
>
Video Input
. Set the video input parameters
described in
Table 4-14
Video input parameters
Parameter
Description
Setting
Name
Specifies the video input port name to
help you identify ports during a
conference.
Do not leave this parameter
blank.
Enter a string of 1 to 64
characters.
Camera type
Specifies the type of the camera
connected. The endpoint supports
cameras of multiple manufacturers and
models.
The default value is
VPC600/VPC620
.
The control commands vary
with different cameras.
Therefore, select the camera
type correctly to ensure that the
camera can be controlled
properly.
Serial port
Specifies the serial port that is connected
to the camera control interface. You can
select either
COM1
or
COM2
.
The default value for the 1
MAIN IN port is
COM2
while
that for other video input ports
is
None
.
Select the serial port that is
being used. Otherwise, the
camera cannot be controlled.
Initial
position
Specifies the position of the camera after
startup.
The default value is
Auto
.