SmartACU2000B smart array controller
User Manual (with PID modules, 800 V AC)
2 Overview
Issue 05 (2019-01-20)
Copyright © Huawei Technologies Co., Ltd.
20
Components in dashed-line boxes are optional.
The smart array controller communicates with PV devices over RS485, PLC, or Ethernet.
When the smart array controller communicates with the inverter over PLC, log in to the embedded
WebUI of the SmartLogger2000, choose
Monitoring
>
MBUS (PLC)
>
Networking Settings
, and set
Networking
to
Enable
(default value). When the smart array controller communicates with the inverter
only over RS485, set
Networking
to
Disable
. For details, see the
SmartLogger2000 User Manual
. (The
WebUI screenshots for SmartLogger V200R002C20SPC119 are used as an example.)
RS485 communication mode
−
All models of smart array controllers support the RS485 communication mode.
−
The SmartLogger connects to the box-type transformer, power meter, inverter, PID
module, PLC CCO module, and other devices that support RS485 communication
over COM ports.
Figure 2-13
RS485 communication mode
The figure displays only major components and cables and is for reference only.
PLC communication mode
−
If a double-column transformer is used, use the smart array controller that supports
the access of one PLC route.