Figure 2-8
CPRI optical cable
(1) DLC connector
(2) Label on the fiber tail
(3) Fiber tail
Pin Assignment
describes the pin assignment for the fiber tails of the CPRI optical cable.
Table 2-7
Pin assignment for the fiber tails of the CPRI optical cable
Label
Color
Connect to...
1A
Orange
RX port on the RRU
1B
Gray
TX port on the RRU
2A
Orange
TX port on the WBBPa
2B
Gray
RX port on the WBBPa
Installation Position
describes the installation positions of the CPRI optical cable.
Table 2-8
Installation positions of the CPRI optical cable
One End
The Other End
CPRI
port on the WBBPa
CPRI_W
port on the RRU
2.3.4 AISG Multi-Wire Cable of the RRU/SRXU
The five-meter-long AISG multi-wire cable connects the RRU/SRXU to the Remote Control
Unit (RCU). If both RRU and SRXU are installed, the AISG multi-wire cable only connects the
SRXU and the RCU. This cable is optional.
Appearance
The cable has a waterproof DB9 connector at one end and a standard AISG female connector at
the other end, as shown in
RRU
User Guide
2 RRU and SRXU Hardware
Issue 01 (2008-04-18)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd