HUAWEI MU739 HSPA+ LGA Module
Hardware Guide
RF Specifications
Issue 01 (2011-08-24)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
40
Operating Band
Tx
Rx
UMTS Band VIII
880 MHz–915 MHz
925 MHz–960 MHz
GSM 850
824 MHz–849 MHz
869 MHz–894 MHz
GSM 900
880 MHz–915 MHz
925 MHz–960 MHz
GSM 1800(DCS)
1710 MHz–1785 MHz
1805 MHz–1880 MHz
GSM 1900(PCS)
1850 MHz–1910 MHz
1930 MHz–1990 MHz
4.4 Conducted RF Measurement
4.4.1
Test Environment
Test instrument
R&S CMU200
、
Agilent E5515C
Power supply
Keithley 2303
、
Agilent 33619
RF cable for testing
Rosenberger Precision Microwave Cable
The compensation for different frequency bands relates to the cable and the test
environment.
The instrument compensation needs to be set according to the actual cable conditions.
4.4.2
Test Standards
Huawei modules meet all 3GPP test standards relating to both 2G and 3G. Each
module passes strict tests at the factory and thus the quality of the modules is
guaranteed.
4.5 Conducted Rx Sensitivity and Tx Power
4.5.1
Conducted Receive Sensitivity
The conducted receive sensitivity is a key parameter that indicates the receiver
performance of MU739. The conducted receive sensitivity refers to the weakest signal
that the module at the antenna port can receive. The BER must meet the 3GPP
protocol requirements in the case of the minimum signal.
The
3GPP Protocol Claim
column in Table 4-2 lists the required minimum values,
and the
Test Value
column lists the tested values of MU739.
draft2