IRD6000
User Guide
3 Troubleshooting
Issue 02 (2012-12-05)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
42
Step 4
Replace the BNC cable with a new one that can work properly and ensure that the ASI output
cable and connector are connected securely.
----End
Emergency Maintenance for IP Output Exception
Step 1
Check that the output IP channel for the program is shut down. Ensure that the IP channel is
open and the program has outputted to the relevant IP channel.
Step 2
Check that the signal reception is normal.
Step 3
Check that the correct reception parameters have been set for the receiving devices, and that
the receiving device's multicast address, port, and protocol are the same as those of the
IRD6000.
Step 4
Ensure that the scrambled program is properly descrambled.
Step 5
Replace the network cable and ensure that its connector is connected properly.
----End