Figure 3-7
Time Configuration tab page
Step 2
Select a time zone from the
Time zone
drop-down list box.
Step 3
Select a time calibration mode and set related parameters. For details, see
NOTE
The time calibration modes include
Manual Time Sync
and
NTP
.
Manual Time Sync
indicates that you can
directly set the camera time.
NTP
indicates that the camera can be time-synchronized with the NTP server in
the network. The two modes cannot be configured at the same time.
Table 3-7
Selecting a time calibration mode
Parameter
Description
Manual Time Sync
1. Select
Manual Time Sync
.
2. Click the
Time
text box.
The dialog box for setting the date and time is displayed.
3. Set the date and time and click
OK
.
The system returns to the time setting page.
NOTE
To time-synchronize the camera with the PC, click
Today
.
NTP
1. Select
NTP
.
2. Set the NTP server IP address or domain name as prompted
and set the interval for time-synchronizing the camera with
the NTP server.
Step 4
Click
Save
.
----End
3.5 Selecting a Stream Package
A stream package is a collection of predefined configurations of video and audio stream
parameters. By configuring and invoking a stream package, you can quickly utilize predefined
video and audio stream configurations.
Procedure
Step 1
Choose
Settings
>
Basic Configuration
>
Stream Package
.
The
Stream Package
page is displayed, as shown in
.
IPC6221-VRZ-SP
Configuration Guide
3 Setting Basic Parameters
Issue 02 (2016-04-06)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
21