Com
pone
nt
No.
Applic
able
Scope
Check Item
16
Outdoor
AP
Cable connectors are secured on cables and sealed to prevent
water intrusion. The outlets of cable conduits on a wall are
sealed by waterproof and flame-retardant materials. Drip
loops meeting the minimum bending radius requirement are
made on the network cable segment that stretches indoor.
17
Outdoor
AP
Do not deploy cables overhead between two buildings.
18
General
Waterproof labels (providing device names and cable
directions) are filled and attached to signal cables correctly.
Each label is attached 20 mm to 100 mm from the
corresponding cable connector.
19
Outdoor
AP
Surge protection measures are taken in the places where the
outdoor APs are installed. The outdoor APs, antennas, and
signal cables are deployed within 45-degree protection area
of a lightning rod.
20
Outdoor
AP
The bare wires of network and feeder cables should be
covered by the winding pipes, flexible metal conduit, PVC
pipes, or galvanization pipes. The cable outlet and inlet are
sealed to prevent dusts.
Anten
na
1
General
The installation positions of antennas should comply with the
engineering design and antennas should be securely and
reliably installed.
2
General
There should be no obstacles in the major coverage direction
of antennas. The direction and downlink tilt of antennas
should be adjusted based on the coverage targets.
3
General
There should not be metal subjects within 1 m around an
outdoor omnidirectional antenna.
4
General
The azimuth deviation of a directional antenna should be
within 5 degrees and the tilt deviation within 0.5 degree.
5
Outdoor
antenna
The antennas are fixed using special support that supports
installation of surge protection devices and shall be located
within a 45 degree protection angle of a lightning rod. When
an antenna is mounted to a pole, the distance between the
antenna and top of the pole should be at least 30 cm.
6
Outdoor
antenna
Take waterproof measures on connectors of the antennas and
feeder cables and keep the drain holes of antennas
downwards.
AP8082DN and AP8182DN
Hardware Installation and Maintenance Guide
6 Appendix
Issue 03 (2019-04-01)
Copyright © Huawei Technologies Co., Ltd.
168