Com
pone
nt
No.
Applic
able
Scope
Check Item
9
General
Pigtail layout should meet the following requirements:
l
Pigtails are not strained or twisted at the bent parts. They
are bundled by binding tape with appropriate force.
l
Pigtails can be pulled back and forth easily inside the
cable tie and are not bent at a right angle.
l
Pigtails are not squeezed by other cables or objects.
l
The flange must be fixed.
l
Pigtails are protected with protective tubes or enveloped
in troughs when they are routed outside the cabinet. The
protective tubes are bundled and processed to prevent
cutting.
l
The optical fiber cannot be folded or twisted, and the
pigtail cannot be squeezed. The binding diameter of an
optical fiber must be larger than 6 cm.
l
The pigtail connection points must be clean and dustless.
Fiber connectors and optical ports that are not used must
be protected with protective caps or plugs. Cleaning must
be carried out in strict accordance with Huawei tool
specifications.
10
General
The feeder cables shall not be bent or twisted, with no copper
wire exposed.
11
General
The feeder cable connectors comply with corresponding
standards and are correctly connected, without looseness.
12
General
The feeder cables, power splitter, coupler, and surge
protective devices are connected correctly and reliably in
accordance with specifications.
13
General
Strong current and weak current cables are routed separately.
The power cables, ground cables, and signal cables are
bundled and routed separately (with a spacing of more than
30 mm) to prevent electrical or magnetic interference. Use
shielded cables in places with strong interference.
14
General
When routing cables in walls, place the cables in the cable
troughs or pipes and fix the cables using pipe straps. For non-
metal corrugated pipes, the fixing distance should be about
1000 mm.
15
Outdoor
AP
All outdoor connectors or feeder cable connectors are
properly sealed to prevent water. Wrap the cable using one-
layer PVC insulation tape, three-layer waterproof tape, and
then three-layer PVC insulation tape. The tape shall be
attached evenly and neatly. The network cables shall be
covered with waterproof PG tubes.
AP8082DN and AP8182DN
Hardware Installation and Maintenance Guide
6 Appendix
Issue 03 (2019-04-01)
Copyright © Huawei Technologies Co., Ltd.
167