39
Temperature Switch TS 2-1000
38
| Control menus
The symbols on the previous page side of the display have the following meaning:
,
– First menu point
2
– Scrolling function is available
+
– Last menu point
7 FuncTIOn mOde „ThermOmeTer n1“
In this mode the temperature of the thermometer module N1 is measured and
the value displayed. The maximum and minimum temperature can be reset by
pressing a button “
Ok
”
Name of the mode
,
Temperature
2
Highest and lowest measured temperatures
+
FuncTIOn mOde “ThermOmeTer n1 and n2”
In this mode the temperature of the thermometer modules N1 and N2 are
measured and the value displayed. The maximum and minimum temperature
can be set by pressing a button “
Ok
”
Name of the mode
,
Temperature T1 and T2
2
Highest and lowest measured temperatures
of the external temperature sensor N1
2
Highest and lowest measured temperatures
of the external temperature sensor N2
+
InpuT mOde “ThermOsschalTer n1” (ThermO sWITch)
In this mode the device can be configured as a switch for heating or for cooling.
menu “ThermOschalTer n1” (ThermO sWITch n1)
In this mode the device can be programmed to be a heating or a cooling unit.
InpuT menu “ThermO sWITch n1”
The following menu points are displayed:
T1 EIN (On)
,
T1 AUS (Off)
2
T1 Alarm Min.
2
T1 Alarm Max
2
T1 Alarm delay
2
Relais Zustand bei Fehler
(relay status at malfunction)
2
Piezo
2
Modus starten (start mode)
+
The single parameters have the following meanings:
T1 eIn (On)
In this menu you can enter a temperature at which a connected device is to be
switched ON. Fist, press button
Ok
. The value can be changed with the buttons
pq
, now. The selection is confirmed by pressing the button “
Ok
” and the
device will move to the next menu point.
T1 aus (Off)
In this menu you can enter a temperature at which a connected device is to be
switched OFF. Press button
Ok
. The value can now be changed with the buttons
pq
. The selection is confirmed by pressing the button “
Ok
” and the device will
move to the next menu point.