HTC 80 iD
Maintenance
1.1
37
5.4.9
Check the side duct fan
•
When required, vacuum clean any dust from visible parts of the side duct fan.
•
Also listen to see if there is any jarring sound coming from the side duct fan.
5.5
Every six months (or 600 hours)
5.5.1
Check the fastening of the bolts
•
Check the fastening of all bolts and screws. Tighten if required.
5.6
Every year
5.6.1
Replace sock filters
Warning!
The dust that is sucked up is harmful if inhaled. Follow local regulations and
use breathing protection.
The sock filter must be replaced annually; however, if the daily inspection of the sock
filter shows that the filter should be replaced, this should be done according to Servicing
the sock filter, page
5.6.2
Replace HEPA filters
Warning!
The dust that is sucked up is harmful if inhaled. Follow local regulations and
use breathing protection.
The HEPA filters must be changed once a year, but if the daily inspection shows that the
HEPA filters needs changing, the following points must be done after steps 1 - 5 in
Check HEPA filters, page
1. Discard the defective HEPA filters.
2. Install the new HEPA filters. Take care that it is installed centrally in the HEPA
filter holder and according to the arrow so the right side of the filters are turned
upwards in the dust extractor.
3. Secure the HEPA filters, with the HEPA filter holder and both of its quick
fasteners, to the lower filter holder's hooks.
Summary of Contents for 80 iD
Page 1: ...HTC 80 iD MANUAL GB Translation of manual in original language...
Page 2: ...HTC 80 iD...
Page 8: ...Table of contents HTC 80 iD iv...
Page 26: ...Usage HTC 80 iD 18 1 1 Figure 4 5 Operating position 1 pre separator...
Page 33: ...HTC 80 iD Usage 1 1 25 4 9 1 Removing full Longopac 1 2...
Page 36: ...Usage HTC 80 iD 28 1 1 3 4...
Page 37: ...HTC 80 iD Usage 1 1 29 5 6...