Rev. 02 – April 2015
Standby
Comfort
Press once
BOOST
2h
Press for 3 sec
Press (at least) for 5 sec
BOOST
Timer 24
BOOST
Timer 12
This mode activates the heating element to the maximum power for 2hrs (for safety reasons the maximal
temperature is limited to 29°C).
To exit the “Boost” mode press the
[Boost/timer]
button.
“Boost” mode indication: "Boost/Timer" LED has red color and it blinks.
“Timer24” mode:
Press the
[Boost/Timer]
button for 3 seconds to activate this mode.
The control system activates the
“Boost” mode for 2 hours, after that it returns into “Comfort” mode and
after 2
2 hours the “Boost” mode is started again for 2 hours. This sequence will repeat endlessly.
To exit the “Timer24” mode press the
[Boost/Timer]
button.
NOTE: During the first cycle the duration of the “Comfort” mode is of 21 hours.
“Timer24” indication:
During 2hrs “Boost”: “Boost/Timer” LED blinking green.
During 22hrs “Comfort”: “Boost/Timer” LED permanent green.
“Timer12” mode:
Press the
[Boost/Timer]
button for more than 5 seconds to activate it.
The control system activates the “Boost” mode for 2 hours, after that it returns into “Comfort” mode and after
10 hours the “Boost” mode is started again for 2 hours. This sequence will repeat endlessly.
To exit the “Timer12” mode press the
[Boost/Timer]
button.
NOTE: During the first cycle the duration of the “Comfort” mode is of 9 hours.
“Timer12” indication during 2hrs “Boost”: “Boost/Timer” LED blinking amber.
During 10hrs “Comfort”: “Boost/Timer” LED permanent amber.
NOTE: For safety reasons, the maximal temperature of the ambient during the 2hrs boost is limited to 29°C.
Functional diagram
“SMART Plus”
Electronic control for towel radiators
“Boost” mode:
Press the
[Boost/Timer]
button to activate this operative mode.
Rev.3 agosto 2020