Maintenance
36
2021-03-25
FM 240 MuW Beta Type S Rev.01
distributed by
Procedure
1.
Loosen the lubricating nipples:
−
On Beta 60 to 80
Unscrew all screw-fit lubricating nipples
(a) about 2 turns so as not to damage
the sealing faces.
−
On Beta 60 to 80
Remove all conical lubricating nipples
or the external lubrication ports and
unscrew the lubricating adapters (a)
about 2 turns so as not to damage the
sealing faces.
−
On Beta 100 to 180
Remove all screw-fit or conical
lubricating nipples (a) or the external
lubrication ports and unscrew the
lubricating adapters (b) about 2 turns
so as not to damage the sealing faces.
2.
Move the carriage into the middle. Then unscrew it and lift it off.
Caution! Do not rotate the carriage. It must be refitted in the same
position!
Do not lose the O-rings fitted on the lubricating apertures on the
inside of the carriage.
3.
Detach the clamp fittings from the ends of the cover band and
remove the cover band.
4.
Check the band guide elements, such as
the press rollers (a), lifting rollers (b) and
locating pins, for wear.
−
If the cover band is worn, be sure also
to replace the band guide elements.
Worn guide elements will damage the
new cover band.
−
If the cover band is damaged, only
replace the band guide elements if
they are damaged.
Fit press rollers (a) with the larger
diameter on the outer.
5.
Insert the new cover band with its broader side (with the chamfered
cutting edge) facing downwards and fix it at one end by the clamp
fitting.
6.
Carefully press the cover band into its guideway along its entire
length until it audibly snaps into place. It must not stick out at any
point, otherwise it will be damaged.