Technical data
– Standard model
FM 240 MuW Beta Type S Rev.01
2021-03-25
13
distributed by
Forces and moments - Beta linear unit with spindle drive
Type designation
Dynamic forces [Nm]
Dynamic moments [Nm]
F
X
F
Y
F
Z
-F
Z
M
X
M
Y
M
Z
M
no-load
Beta 60-SSS
4000
600
1800
1200
60
180
120
0,7
Beta 60-SGV
4000
-
-
-
-
-
-
0,7
Beta 70-C-SRS
2000
300
1000
400
35
120
60
0,3
Beta 70-C-SSS
2000
600
1800
1200
60
180
120
0,4
Beta 80-SRS
4000
500
1500
800
50
180
100
0,6
Beta 80-SSS
4000
800
3000
2000
100
250
250
0,8
Beta 80-SGV
6000
-
-
-
-
-
-
1,5
Beta 100-D-SSS
4000
1800
4000
3000
350
750
750
1,5
Beta 110-C-SGV
16000
-
-
-
-
-
-
1,5
Beta 110-SRS
6000
3000
5000
2500
400
800
600
1,5
Beta 110-SSS
6000
2000
8000
4000
300
600
450
1
Beta 120-C-SSS
12000
4000
12000
6000
600
1500
1000
2,0
Beta 140-SRS
6000
2500
5000
3000
350
700
700
1,5
Beta 140-SSS
6000
2500
6000
4000
500
1000
1000
1,8
Beta 140-C-SSS
6000
3200
7500
5000
600
1200
1200
1,8
Beta 165-SGV
18000
-
-
-
-
-
-
3
Beta 165-C-SGV
25000
-
-
-
-
-
-
3,2
Beta 165-SSS
18000
5000
15000
8000
700
1400
1100
3
Beta 180-SSS
12000
6000
12000
6000
1500
3000
1500
2,5
Beta 180-C-SSS
6000
6000
15000
8000
1800
3600
1800
2,5
Figures in ( ) relate to the long carriage.
M
no-load
= No-load torque ±30%
The forces and moments quoted are maximum values for the single load. In the event
of combined loading or simultaneous occurrence of multiple moments or forces, the
individual values must be reduced. In case of doubt consult Technical Support.
Summary of Contents for Beta 100-D-SSS
Page 2: ......