3. Installation
3.1 Installing the burner:
TPK with Scandpell:
The Scandpell can be installed on the right or left side of the TPK.
The boiler is completely symmetrical based around the combustion chamber and the 2 coupling connector
holes for connecting the Scandpell burner.
The burner is connected via one hole, and the coupling connector with an insulated blank is fitted in the
other hole.
TPK:
It is not certain that a burner other than a Scandpell can be installed using either of the holes in the side of
the boiler.
It may instead be necessary to install the burner via the front cleaning access door.
This cleaning access door is not pre-prepared for installation of this kind, and it may require specific
adaptation for the burner in question.
The distance from the front of the boiler to its back wall is 515 mm. This distance must be
sufficient for the wood pellet burner used in order to ensure that it works properly.
The inclination of the feeder tube must not exceed an angle of 45 ° from horizontal.
If not, it cannot be assured that sufficient fuel is brought to the burner.
120 mm
120 mm