4.  Installation 

 

a)  Smoke Liquid

 

 

 

Please use non-inflammable water-based smoke fluid without oil or grease, such as 

VDLSL1

 (1 litre), 

VDLSL5

 (5 

litres), or 

VDLSL5H

 (5 litres high density smoke liquid). 

 

Non-recommended smoke liquid may damage the machine and void the warranty. 

1.  Unplug the device from the mains. 

2.  Unscrew the cap from the tank. 

3.  Carefully pour smoke liquid into the tank, keeping the level below the "Maximum" mark at the back. 

4.  Reposition the cap on the tank. 

 

Remark: Do not operate the device when the tank is open. 

 

b)  Fuse

 

 

 

Only fit or replace a fuse when the device is unplugged from the mains. 

 

Replace a blown fuse with a fuse of the same type and rating (see “

7. Technical Specifications

” on p.3): 

1.  Unplug the device from the mains. 

2.  Unscrew the fuse holder at the back with an appropriate screwdriver. 

3.  Remove the old fuse and install a new one. 

4.  Replace the fuse holder and fasten it with the screwdriver. 

 

c)  Mounting the Device

 

 

 

Have the device installed by a qualified person, respecting EN 60598-2-17 and all other applicable norms. 

 

The construction to which the device is attached should be able to support 10 times the weight of the device for 

one hour without deformation. 

 

The installation must always be secured with a secondary attachment e.g. a safety cable. 

 

Never stand directly below the device when it is being mounted, removed or serviced. Have a qualified technician 

check the device once a year and once before you bring it into service. 

 

Install the device in a location with few passers-by that is inaccessible to unauthorised persons. 

 

Overhead mounting requires extensive experience: calculating workload limits, determining the installation 

material to be used… Have the material and the device itself checked regularly. Do not attempt to install the 

device yourself if you lack these qualifications as improper installation may result in injuries. 

 

Adjust the desired inclination angle via the mounting bracket and tighten the bracket screws. 

 

Make sure there is no flammable material within a 50cm radius of the device. 

 

Have a qualified electrician carry out the electric connection. 

 

Connect the device to the mains with the power plug. Don’t connect it to a dimming pack. 

 

The installation has to be approved by an expert before the device is taken into service. 

 

5. Use

 

 

Connect the device to the mains and flick the power switch at the back of the device to ON. After the warm-up time 

(approx. 4 minutes) the device is ready for use. The remote control is equipped with 2 rotary controls and 3 

pushbuttons with corresponding LEDs: 

 

the "duration" rotary control allows to determine the duration of each activation 

 

the "interval" rotary control allows to determine the interval between activations 

 

the yellow pushbutton activates operation with interval 

 

the red pushbutton activates or deactivates the remote control 

 

the third button selects continuous smoke output. It may happen that the stand-by lamp on the remote control is 

off and the smoke emission stops, even while you are holding the button. It means the device is warming up again 

and will be ready in approx. 2 minutes. This process guarantees an appropriate vaporization temperature and the 

best smoke emission possible. 

Summary of Contents for VDL700SM3

Page 1: ...r when it is not in use Handle the power cord by the plug only There may be some smoke or a particular smell when the device is activated for the first time This is normal and any smoke or smell will...

Page 2: ...ion with few passers by that is inaccessible to unauthorised persons Overhead mounting requires extensive experience calculating workload limits determining the installation material to be used Have t...

Page 3: ...g cleaning liquid and rinse the tank thoroughly with distilled water Never use regular water for cleaning or rinsing 7 Technical Specifications Power supply max 230VAC 50Hz Power consumption max 700W...

Page 4: ...sioneel gebruik op podia in disco s theaters enz U mag dit toestel enkel binnenshuis gebruiken met een wisselspanning van maximum 230Vac 50Hz Rookmachines zijn niet ontworpen voor continue werking reg...

Page 5: ...r een expert 5 Gebruik Sluit het toestel aan op het lichtnet en zet de stroomschakelaar achteraan het toestel op ON Na de opwarmtijd ong 4 minuten is het toestel klaar voor gebruik De afstandsbedienin...

Page 6: ...de ce manuel et votre revendeur d clinera toute responsabilit pour les probl mes et les d fauts qui en r sultent Un technicien qualifi doit s occuper de l installation et de l entretien Ne branchez p...

Page 7: ...uide de fum e non recommand e peut endommager l appareil et annule la garantie 1 D branchez l appareil du r seau lectrique 2 D vissez le bouchon du r servoir 3 Versez prudemment du liquide de fum e da...

Page 8: ...e possible 6 Nettoyage et entretien 1 Serrez les crous et les vis et v rifiez qu ils ne rouillent pas 2 Le bo tier les lentilles les supports de montage et la construction portante ne peuvent pas tre...

Page 9: ...as especificaciones No aplaste el cable de alimentaci n y prot jalo contra posibles da os causados por alg n tipo de superficie afilada Si es necesario pida a su distribuidor reemplazar el cable de al...

Page 10: ...ro con un destornillador adecuado 2 Quite el fusible fundido y reempl celo 3 Vuelva la tapa en su lugar y atorn llela c Instalaci n del aparato Respete la directiva EN 60598 2 17 y toda norma nacional...

Page 11: ...c 3 Las partes m viles no pueden mostrar ning n rastro de desgaste y deben estar bien equilibradas 4 No da e los cables de alimentaci n Contacte con un t cnico especializado para instalar el aparato 5...

Page 12: ...e das Ger t solange ausgeschaltet bis es die Zimmertemperatur erreicht hat Der Aufbau des Ger tes entspricht der Schutzklasse I Gem den Vorschriften muss das Ger t geerdet sein Der elektrische Anschlu...

Page 13: ...enm chtige Ver nderungen sind aus Sicherheitsgr nden verboten Verwenden Sie das Ger t nur f r Anwendungen beschrieben in dieser Bedienungsanleitung sonst kann dies zu Sch den am Produkt f hren und erl...

Page 14: ...Netzschalter in Position ON Nach der Aufheizzeit etwa 4 Minuten ist das Ger t gebrauchsfertig Die Fernbedienung ist mit 2 Drehkn pfen und 3 Druckkn pfen mit entsprechenden LEDs ausger stet der Duratio...

Page 15: ...normales Wasser 7 Technische Daten Spannungsversorgung max 230VAC 50Hz Verbrauch max 700W Sicherung F 5A 250VAC 5 x 20mm Best Nr FF5N Nebelaussto 100m Min Aufheizzeit etwa 4 Minuten Fluidverbrauch et...

Reviews: