Specifications
Environmental specifications
Specification
Value
Temperature range
1
Operating
10°C to 35°C (50°F to 95°F)
Shipping
-40°C to 70°C (-40°F to 158°F)
Maximum wet bulb temperature
28°C (82.4°F)
Relative humidity (noncondensing)
2
Operating
10% to 90%
Nonoperating
5% to 95%
1
All temperature ratings shown are for sea level. An altitude derating of 1°C per 300 m (1.8°F per 1,000 ft) to 3,048 m
(10,000 ft) is applicable. No direct sunlight allowed.
2
Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F). Altitude maximum for
storage corresponds to a pressure minimum of 70 kPa.
Chassis specifications
Specification
Value
Height
18.96 cm (7.46 in)
Depth
84.91 cm (33.43 in)
Width
44.33 cm (17.45 in)
Weight (fully loaded, with three XL450 servers)
99.79 kg (220.00 lb)
Weight, empty
43.09 kg (95.00 lb)
Power supply specifications
Depending on installed options, the server is configured with one of the following power supplies:
•
HPE 800W Flex Slot Platinum Hot-plug Power Supply
on page 48
•
HPE 800W Flex Slot -48VDC Hot-plug Power Supply
on page 48
•
HPE 800W Flex Slot Titanium Plus Hot-plug Power Supply
on page 50
•
HPE 800W Flex Slot Universal Hot-plug Power Supply
on page 51
•
HPE 1400W Flex Slot Platinum Plus Hot-plug Power Supply
on page 51
For detailed power supply specifications, see the QuickSpecs on the Hewlett Packard Enterprise website
(
http://www.hpe.com/info/proliant/powersupply
).
Specifications
47