Autochanger Error Codes
Jukebox Micro-Move Error Codes
Appendix B
B-42
17
MAILSLOT IO
Makes a combination of moves with a PASS/
FAIL result. It moves an optical disk from the
lowest-numbered full slot to the mailslot with
a random flip. It then moves the cartridge
back to its original slot with its original
orientation. This test displays if there are no
disks in the jukebox or if all storage slots are
full. The drives and mailslot must be empty.
18
EMPTY DRIVES
Moves cartridges out of the drive
mechanism(s) and returns them to their
storage slots.
20
PLUNGE FULL
SPD
Allows the disk transport mechanics to be
run at full speed. This configuration should
always be used when the jukebox is being
used.
21
PLUNGE 1/2
SPD
Allows the disk transport mechanics to be
run at half speed. Use this configuration for
diagnostic purposes only.
22
PLUNGE 1/4
SPD
Allows the mechanics to be run at quarter
speed. Use this configuration for diagnostic
purposes only.
24
FILL PICKER
Moves an optical disk into the disk transport
mechanism from the first storage slot
containing a disk.
25
EMPTY
PICKER
Moves an optical disk from the disk transport
mechanism to its home storage slot location if
that location is known, otherwise the disk is
placed into the first available empty storage
slot.
26
CLEAR SOFT
LOG
The runtime log (soft error log) is initialized
to all zeros.
Table B-12
Diagnostic Tests (EXCEPT for models 40fx, 80ex, 125ex, and
220mx)
No.
Front Panel
Test Name
Description
Summary of Contents for SureStore Optical 2600fx
Page 1: ...optical drive and library SCSI 2 command reference for models fx ex and mx ...
Page 11: ...Contents x ...
Page 20: ...Chapter 1 1 1 SCSI Command Overview 1 SCSI Command Overview ...
Page 38: ...Chapter 2 2 1 Drive Commands SCSI 2 Drive Commands 2 SCSI 2 Drive Command Set ...
Page 187: ...SCSI 2 Drive Command Set Write Long Command DFH Chapter 2 2 150 ...
Page 188: ...Chapter 3 3 1 Jukebox SCSI 2 Commands 3 Jukebox SCSI 2 Command Set ...
Page 264: ...Appendix A A 1 Drive Error Codes A Drive Error Codes ...
Page 287: ...Drive Error Codes DSP Error Codes Appendix A A 24 ...
Page 288: ...Appendix B B 1 Autochanger Error Codes B Autochanger Error Codes ...
Page 339: ...Autochanger Error Codes Jukebox Micro Move Error Codes Appendix B B 52 ...
Page 340: ...Appendix C C 1 Field Replaceable Units C Field Replaceable Units FRUs ...
Page 345: ...Field Replaceable Units FRUs HP Field Replaceable Units FRUs Appendix C C 6 ...
Page 346: ...Appendix D D 1 Micro Macro Moves D Micro Macro Moves ...
Page 369: ...Micro Macro Moves HP Surestore Optical Micro Move IDs Appendix D D 24 ...
Page 370: ...Appendix E E 1 Disconnect Timeouts E Disconnect Timeout Settings ...
Page 373: ...Disconnect Timeout Settings Disconnect Timeout Settings Appendix E E 4 ...
Page 377: ...Index 4 ...