Disconnect Timeout Settings
Disconnect Timeout Settings
Appendix E
E-2
Disconnect Timeout Settings
The following commands will cause a SCSI disconnect. It is useful to
know what the maximum times for disconnect are so driver timeouts can
be set appropriately.
NOTE
In Table E-1 the maximum disconnect time is represented by the nominal
number of seconds plus the number of levels of error recovery times 60.
You can see the maximum time can be very long. An appropriate timeout
may be a compromise between the nominal time and maximum time.
Table E-1
Timeout Settings
Command
Nominal
Disconnect
Time
(seconds)
Maximum
Disconnect
Time
Levels of
Error
Recovery
Exchange Medium
14
600 sec
6
Initialize Element
Status
120
600 sec
6
Move Medium
5
600 sec
6
Position To Element
5
600 sec
6
Prevent/Allow Media
Removal
10
600 sec
6
Read Element Status
120
a
600 sec
6
Release
10
600 sec
6
Reserve
10
600 sec
6
Rezero Unit
120
600 sec
6
Send Diagnostic
600
b
600 sec
6
Rotate
5
600 sec
6
Summary of Contents for SureStore Optical 2600fx
Page 1: ...optical drive and library SCSI 2 command reference for models fx ex and mx ...
Page 11: ...Contents x ...
Page 20: ...Chapter 1 1 1 SCSI Command Overview 1 SCSI Command Overview ...
Page 38: ...Chapter 2 2 1 Drive Commands SCSI 2 Drive Commands 2 SCSI 2 Drive Command Set ...
Page 187: ...SCSI 2 Drive Command Set Write Long Command DFH Chapter 2 2 150 ...
Page 188: ...Chapter 3 3 1 Jukebox SCSI 2 Commands 3 Jukebox SCSI 2 Command Set ...
Page 264: ...Appendix A A 1 Drive Error Codes A Drive Error Codes ...
Page 287: ...Drive Error Codes DSP Error Codes Appendix A A 24 ...
Page 288: ...Appendix B B 1 Autochanger Error Codes B Autochanger Error Codes ...
Page 339: ...Autochanger Error Codes Jukebox Micro Move Error Codes Appendix B B 52 ...
Page 340: ...Appendix C C 1 Field Replaceable Units C Field Replaceable Units FRUs ...
Page 345: ...Field Replaceable Units FRUs HP Field Replaceable Units FRUs Appendix C C 6 ...
Page 346: ...Appendix D D 1 Micro Macro Moves D Micro Macro Moves ...
Page 369: ...Micro Macro Moves HP Surestore Optical Micro Move IDs Appendix D D 24 ...
Page 370: ...Appendix E E 1 Disconnect Timeouts E Disconnect Timeout Settings ...
Page 373: ...Disconnect Timeout Settings Disconnect Timeout Settings Appendix E E 4 ...
Page 377: ...Index 4 ...