1.
Connect DP-1 on the storage controller in slot 1 to DP-1 on the I/O module in slot 1 of the first drive
enclosure.
2.
Connect DP-2 on the I/O module in slot 1 of the first drive enclosure to DP-1 on the I/O module in slot 1 of
the second drive enclosure.
3.
Connect DP-1 on the storage controller in slot 2 to DP-1 on the I/O module in slot 2 of the second drive
enclosure.
4.
Connect DP-2 on the I/O module in slot 2 of the second drive enclosure to DP-1 on the I/O module in slot 2
of the first drive enclosure.
Connecting to three drive enclosures
1
2
3
4
Figure 20: Three drive enclosure cabling configuration
1. Array enclosure
3. Drive enclosure 2
2. Drive enclosure 1
4. Drive enclosure 3
1.
Connect DP-1 on the storage controller in slot 1 to DP-1 on the I/O module in slot 1 of the first drive
enclosure.
2.
Connect DP-2 on the I/O module in slot 1 of the first drive enclosure to DP-1 on the I/O module in slot 1 of
the second drive enclosure.
3.
Connect DP-2 on the I/O module in slot 1 of the second drive enclosure to DP-1 on the I/O module in slot 1
of the third drive enclosure.
4.
Connect DP-1 on the storage controller in slot 2 to DP-1 on the I/O module in slot 2 of the third drive
enclosure.
5.
Connect DP-2 on the I/O module in slot 2 of the third drive enclosure to DP-1 on the I/O module in slot 2 of
the second drive enclosure.
6.
Connect DP-2 on the I/O module in slot 2 of the second drive enclosure to DP-1 on the I/O module in slot 2
of the first drive enclosure.
Bonded interface configuration
In an HPE StoreVirtual 3200 Storage System, the 1GbE and 10GbE/10GBase-T interfaces on both iSCSI and
Fibre Channel Ethernet networks must be configured using bonded interfaces.