The
-h HOSTLIST
option lists the nodes to check. To also check standbys, include the
-b
option.
To view results only for file serving nodes that failed a check, include the
-f
argument. The
-s
option expands the report to include information about the file system and its segments. The
-v
option produces detailed information about configuration checks that received a Passed result.
For example, to view a detailed report for file serving nodes xs01.hp.com:
<installdirectory>/bin/ibrix_haconfig -i -h xs01.hp.com
--------------- Overall HA Configuration Checker Results ---------------
FAILED
--------------- Overall Host Results ---------------
Host HA Configuration Power Sources Backup Servers Auto Failover Nics Monitored
Standby Nics HBAs Monitored
xs01.hp.com FAILED PASSED PASSED PASSED FAILED
PASSED FAILED
--------------- Server xs01.hp.com FAILED Report ---------------
Check Description Result Result Information
================================================ ====== ==================
Power source(s) configured PASSED
Backup server or backups for segments configured PASSED
Automatic server failover configured PASSED
Cluster & User Nics monitored
Cluster nic xs01.hp.com/eth1 monitored FAILED Not monitored
User nics configured with a standby nic PASSED
HBA ports monitored
Hba port 21.01.00.e0.8b.2a.0d.6d monitored FAILED Not monitored
Hba port 21.00.00.e0.8b.0a.0d.6d monitored FAILED Not monitored
34
Configuring failover