Description
Field
Operational state of the port.
Port State
WWPN of the standby port for this port (standby-paired HBAs only).
Backup Port WWN
Whether HBA monitoring is enabled for this port.
Monitoring
Checking the High Availability configuration
Use the
ibrix_haconfig
command to determine whether High Availability features have been
configured for specific file serving nodes. The command checks for the following features and
provides either a summary or a detailed report of the results:
•
Programmable power source
•
Standby server or standby segments
•
Cluster and user network interface monitors
•
Standby network interface for each user network interface
•
HBA port monitoring
•
Whether automated failover is on
For each High Availability feature, the summary report returns one of the following results for each
tested file serving node and optionally for their standbys:
•
Passed.
The feature has been configured.
•
Warning.
The feature has not been configured, but the significance of the finding is not clear.
For example, the absence of discovered HBAs can indicate either that the HBA monitoring
feature was not configured or that HBAs are not physically present on the tested servers.
•
Failed.
The feature has not been configured.
The detailed report includes an overall result status for all tested file serving nodes and describes
details about the checks performed on each High Availability feature. By default, the report includes
details only about checks that received a Failed or a Warning result. You can expand the report
to include details about checks that received a Passed result.
Viewing a summary report
Executing the
ibrix_haconfig
command with no arguments returns a summary of all file serving
nodes. To check specific file serving nodes, include the
-h HOSTLIST
argument. To check standbys,
include the
-b
argument. To view results only for file serving nodes that failed a check, include
the
-f
argument.
<installdirectory>/bin/ibrix_haconfig -l [-h HOSTLIST] [-f] [-b]
For example, to view a summary report for file serving nodes xs01.hp.com and xs02.hp.com:
<installdirectory>/bin/ibrix_haconfig -l -h xs01.hp.com,xs02.hp.com
Host HA Configuration Power Sources Backup Servers Auto Failover
Nics Monitored Standby Nics HBAs Monitored
xs01.hp.com FAILED PASSED PASSED PASSED
FAILED PASSED FAILED
xs02.hp.com FAILED PASSED FAILED FAILED
FAILED WARNED WARNED
Viewing a detailed report
Execute the
ibrix_haconfig -i
command to view the detailed report:
<installdirectory>/bin/ibrix_haconfig -i [-h HOSTLIST] [-f] [-b] [-s] [-v]
Cluster high availability