Error codes
Table 4 Error codes
Error code
Description
Required action
C
n
01
Con
fi
guration error—Hardware not
supported
Log error, check hardware and cable
connections.
F
n
00 – F
n
67
Firmware error
Log error, restart enclosure. If error persists,
contact HP support.
H
n
00 – H
n
29
Hardware error—Controller error
Log error, contact HP support, replace
controller.
H
n
30
Hardware error—Fatal ECC error
Log error, contact HP support, replace
cache module.
H
n
31–66
Hardware error—Controller error
Log error, contact HP support, replace
controller.
H
n
67
Hardware error—SAS expander error
Log error, contact HP support, verify
cabling. If error persists, replace controller.