The second character indicates the controller signalling the error:
•
1—Controller 1
•
2—Controller 2
The third and fourth characters indicate the speci
fi
c error on the controller:
(Displayed by pressing the up
or down arrow on the seven-segment display.)
Example 1. Error code example
C101
= Controller 1, unsupported con
fi
guration
POST codes
At power on, the enclosure goes through a series of tests called Power On Self Tests (POST). As each test
runs, a code is displayed on the seven-segment display indicating the current test being run.
Table 3 POST codes
POST code Description
SU
Controller
fi
rmware has been unpacked and launched.
S1
Port setup is complete.
S2
Pause / Wait for Expander Discovery is complete.
S3
Static Class Construction complete / Valid Stack Range has been set.
S4
PCI express cores have been initialized.
S5
PCI express core 0 link has been activated.
S6
Battery initialization complete.
S7
Memory Pools have been registered.
S8
The Serial Output Buffer initialization is complete.
S9
Product ID and controller ID have been set.
SA
OS Services object construction is complete.
SB
HCS initialization is complete.
SC
Task creation is complete.
9100c Extreme Data Storage System user guide
23
Summary of Contents for StorageWorks 9100 - Extreme Data Storage System
Page 5: ...Figures 1 Exploded view 32 9100c Extreme Data Storage System user guide 5 ...
Page 10: ...10 About this guide ...
Page 12: ...12 Overview ...
Page 32: ...nl Figure 1 Exploded view 32 Parts catalog ...
Page 34: ...34 Parts catalog ...
Page 40: ...40 Electrostatic discharge ...
Page 42: ...42 Specifications ...
Page 47: ...Power cord statement for Japan 9100c Extreme Data Storage System user guide 47 ...