Table 2 LED Hard drive LED combinations
Online/activity LED (green)
Fault/UID LED (amber/blue)
Interpretation
On, off, or
fl
ashing
Alternating amber and blue
The drive has failed, or a predictive
failure alert has been received for
this drive; it also has been selected
by a management application.
On, off, or
fl
ashing
Steadily blue
The drive is operating normally,
and it has been selected by a
management application.
On
Amber,
fl
ashing regularly (1 Hz)
A predictive failure alert has been
received for this drive. Replace the
drive as soon as possible.
On
Off
The drive is online, but it is not
currently active.
Flashing regularly (1 Hz)
Amber,
fl
ashing regularly (1 Hz)
Do not remove the drive. Removing
a drive may terminate the current
operation and cause data loss.
The drive is part of an array that
is undergoing capacity expansion
or a stripe size migration, but a
predictive failure alert has been
received for this drive. To minimize
the risk of data loss, do not replace
the drive until the expansion or
migration is complete.
Flashing regularly (1 Hz)
Off
Do not remove the drive.
Removing a drive may terminate
the current operation and cause
data loss.
The drive is rebuilding,
or it is part of an array that is
undergoing capacity expansion or
a stripe size migration.
Flashing irregularly
Amber,
fl
ashing regularly (1 Hz)
The drive is active, but a predictive
failure alert has been received for
this drive. Replace the drive as
soon as possible.
Flashing irregularly
Off
The drive is active, and it is
operating normally.
Off
Steadily amber
A critical fault condition has been
identi
fi
ed for this drive, and the
controller has placed it of
fl
ine.
Replace the drive as soon as
possible.
Off
Amber,
fl
ashing regularly (1 Hz)
A predictive failure alert has been
received for this drive. Replace the
drive as soon as possible.
Off
Off
The drive is of
fl
ine, a spare, or not
con
fi
gured as part of an array.
NOTE:
Predictive failure alerts are generated by system management software and occur only when the
enclosure is connected to a Smart Array controller. The ExDS9100c includes a Smart Array controller.
9100c Extreme Data Storage System user guide
21
Summary of Contents for StorageWorks 9100 - Extreme Data Storage System
Page 5: ...Figures 1 Exploded view 32 9100c Extreme Data Storage System user guide 5 ...
Page 10: ...10 About this guide ...
Page 12: ...12 Overview ...
Page 32: ...nl Figure 1 Exploded view 32 Parts catalog ...
Page 34: ...34 Parts catalog ...
Page 40: ...40 Electrostatic discharge ...
Page 42: ...42 Specifications ...
Page 47: ...Power cord statement for Japan 9100c Extreme Data Storage System user guide 47 ...